2011
DOI: 10.1590/s0103-50532011000900015
|View full text |Cite
|
Sign up to set email alerts
|

Fast and simultaneous determination of Pb2+ and Cu2+ in water samples using a solid paraffin-based carbon paste electrode chemically modified with 2-aminothiazole-silica-gel

Abstract: Um eletrodo de pasta de carbono preparado com parafina sólida como aglutinante e quimicamente modificado com sílica funcionalizada com grupos 2-aminotiazol foi empregado na quantificação simultânea de Pb 2+ e Cu 2+ em amostras de água por meio de voltametria de redissolução anódica. O presente método emprega um tempo curto de pré-concentração (180 s), o qual permitiu a quantificação simultânea e confiável de Pb 2+ e Cu 2+ de maneira bastante rápida. Foram obtidos limites de detecção de 7,3 e 90 nmol L −1 para … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
3
0
3

Year Published

2014
2014
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 38 publications
(62 reference statements)
2
3
0
3
Order By: Relevance
“…The narrowest potential window was found in 0.1 mol L -1 KOH, which is in close agreement with the previously reported for silicone-rubber CPEs. 35 The useful potential windows observed in the other supporting electrolytes were close to 1.5 V, and they are comparable with the potential window obtained with silicone-rubber 35 and solid-paraffin 8 CPEs. Nujol ® -CPE has presented narrower useful potential window and higher background currents regardless of the supporting electrolyte ( Figure S4, SI section).…”
Section: Pdms-cpe Characterizationsupporting
confidence: 79%
See 1 more Smart Citation
“…The narrowest potential window was found in 0.1 mol L -1 KOH, which is in close agreement with the previously reported for silicone-rubber CPEs. 35 The useful potential windows observed in the other supporting electrolytes were close to 1.5 V, and they are comparable with the potential window obtained with silicone-rubber 35 and solid-paraffin 8 CPEs. Nujol ® -CPE has presented narrower useful potential window and higher background currents regardless of the supporting electrolyte ( Figure S4, SI section).…”
Section: Pdms-cpe Characterizationsupporting
confidence: 79%
“…A chemically modified CPE is obtained by the simple addition of the chemical modifier to the mixture between graphite powder and the binder agent. Several chemical modifiers have been used such as ion exchange materials, 6,7 silica, and organofunctionalized silicas, [8][9][10][11] metallic nanoparticles, 12,13 oxides 14 and complexes, 15,16 carbon nanotubes, 17 etc. These materials have allowed the preparation of CPEs with superior analytical performance extending their application to trace analysis of different kinds of analytes, such as metal ions, 18,19 drugs, 20,21 organic pollutants, 22 and biologically important compounds.…”
Section: Introductionmentioning
confidence: 99%
“…The currents were measured in triplicate and their aver- age allowed obtaining the analytical curves for each metallic ion ( Figure 9B). The linear dynamic ranges, detection limits (three times the signal blank/slope) [39], and linear equations for the metal ions are presented in Table 2.…”
mentioning
confidence: 99%
“…Os agentes modificadores à base de sílica são empregados frequentemente para modificação de CPEs aplicados na determinação de metais em diversas matrizes [55,[56][57]58].…”
Section: Eletrodos De Pasta De Carbono Quimicamente Modificados -Cmcpeunclassified
“…Com estes resultados, é possível verificar que o eletrodo preparado com óleo mineral Nujol ® apresenta melhor resposta voltamétrica para oxidação de PROP, fornecendo pico voltamétrico mais intenso e definido em relação ao eletrodo preparado com parafina. A pasta preparada com parafina é mais compacta e rígida, além disso, apresenta maior hidrofobicidade em relação a pasta preparada com Nujol ® , dificultando o contato eletrodo-analito, resultando assim em um pico com baixa intensidade [55]. O bom desempenho de CPE preparados com óleo mineral Nujol ® para a análise e determinação de fármacos, especialmente os da classe de β-bloqueadores, é relatado em algumas publicações [35,42].…”
Section: Análise Das Amostras Por Voltametria De Pulso Diferencialunclassified