2009
DOI: 10.1590/s0103-50532009000800011
|View full text |Cite
|
Sign up to set email alerts
|

Cadmium and lead cloud point preconcentration and determination in tobacco samples by thermospray flame furnace atomic absorption spectrometry

Abstract: A espectrometria de absorção atômica com forno tubular na chama (TS-FF-AAS) foi empregada para a determinação de Cd e Pb em diferentes tipos de amostras brasileiras de tabacos após a pré-concentração no ponto nuvem (CP) otimizada por planejamento Doehlert. Para a separação das fases no procedimento por ponto nuvem, Triton ® X-114 e 2-(bromo-2-piridilazo)-5-dietilaminofenol (Br-PADAP) foram utilizados como surfactante não iônico e agente complexante, respectivamente. Cádmio e chumbo foram determinados após dige… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
5
1
3

Year Published

2009
2009
2021
2021

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 23 publications
2
5
1
3
Order By: Relevance
“…Therefore, the element has been included in the list of harmful and potentially harmful constituents in tobacco products and tobacco smoke according to US Food and Drug Administration (FDA). 53 The amount of Cd 2+ obtained in the present study was slightly higher and lower than those amounts determined by Andrade et al 54 and Lemos et al, 55 respectively, in cigarettes commercialized in Brazil. The amount of Cd 2+ also determined in certified reference (TORT-2, lobster hepatopancreas) by this method (26.47 ± 0.25 µg g −1 , n = 3) was statistically equal to the certified value (26.7 ± 0.6 µg g −1 ) with 95% confidence interval (Student's t-test), thus confirming the accuracy of the proposed method even for biological sample submitted to acid digestion.…”
Section: Application Of the Proposed Methodscontrasting
confidence: 48%
“…Therefore, the element has been included in the list of harmful and potentially harmful constituents in tobacco products and tobacco smoke according to US Food and Drug Administration (FDA). 53 The amount of Cd 2+ obtained in the present study was slightly higher and lower than those amounts determined by Andrade et al 54 and Lemos et al, 55 respectively, in cigarettes commercialized in Brazil. The amount of Cd 2+ also determined in certified reference (TORT-2, lobster hepatopancreas) by this method (26.47 ± 0.25 µg g −1 , n = 3) was statistically equal to the certified value (26.7 ± 0.6 µg g −1 ) with 95% confidence interval (Student's t-test), thus confirming the accuracy of the proposed method even for biological sample submitted to acid digestion.…”
Section: Application Of the Proposed Methodscontrasting
confidence: 48%
“…These results are almost comparable with some studies done in literature [18][19][20]. Comparison with the other SPE methods…”
Section: Recovery (%)supporting
confidence: 90%
“…A more conventional CPE procedure was applied for the determination of Cd and Pb in tobacco samples using thermospray flame furnace atomic absorption spectrometry, TS-FF-AAS. 22 A nickel tube atomizer was used for improving the efficiency of atom cloud formation after sample introduction by thermospray employing a capillary ceramic tube. The efficiency of nickel and titanium tubes was compared for determination of Cu in biological samples and foods.…”
Section: Biological Materialsmentioning
confidence: 99%