2006
DOI: 10.1590/s0103-50532006000300014
|View full text |Cite
|
Sign up to set email alerts
|

Minimization of sample pretreatment for Al, Cu and Fe determination in coconut water by electrothermal atomic absorption spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
11
0
2

Year Published

2010
2010
2022
2022

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 18 publications
(13 citation statements)
references
References 16 publications
(30 reference statements)
0
11
0
2
Order By: Relevance
“…35,36 On-the-coil sample decomposition followed by WCAES has also been successfully applied to sh, beverage and biodiesel samples. Graphite tubes and tungsten laments have been used to decompose sample matrix and improve precision and accuracy in determinations by ICP-MS, 32,33 ICP OES 34 and graphite furnace atomic absorption spectrometry (GFAAS).…”
Section: Resultsmentioning
confidence: 99%
“…35,36 On-the-coil sample decomposition followed by WCAES has also been successfully applied to sh, beverage and biodiesel samples. Graphite tubes and tungsten laments have been used to decompose sample matrix and improve precision and accuracy in determinations by ICP-MS, 32,33 ICP OES 34 and graphite furnace atomic absorption spectrometry (GFAAS).…”
Section: Resultsmentioning
confidence: 99%
“…In the case of Cu determination, a volume of 10 μL of matrix modifier (1% v/v HNO 3 +15% v/v H 2 O 2 ) was coinjected into the graphite atomizer with 15 μL of the analytical solutions or sample. The detailed procedure was described in the literature (Naozuka and Oliveira 2006).…”
Section: Methodsmentioning
confidence: 99%
“…The complex chemical composition of green coconut water includes carbohydrates (fructose and glucose); proteins; lipids; vitamins (Jackson et al 2004;Jayalekshmy et al 1986;Jayalekshmy et al 1988); minerals, such as Al, Cu, Ca, Cu, Fe, K, Mg, Mn, Na, Se, and Zn (Aleixo et al 2000;Chumbimuni-Torres and Kubota 2006;de Sousa et al 2005ade Sousa et al , b, 2006Naozuka and Oliveira 2006;Oliveira et al 2005;Richter et al 2005;Santoso et al 1996); and chloride, phosphate, sulfate, malate, and ascorbate (Richter et al 2005).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…A GF AAS reúne condições favoráveis para a determinação de elementos em níveis de traço, tais como baixo limite de detecção (na ordem de µg L -1 ), boa seletividade e sensibilidade (NAOZUKA & OLIVEIRA, 2006). Essas características são devido ao tipo de atomizador utilizado, um forno de grafite, que permite com que toda a amostra depositada no interior do tubo de grafite seja processada e os elementos de interesse atomizados em um curto espaço de tempo, em uma atmosfera inerte.…”
unclassified