2000
DOI: 10.1590/s0103-50532000000400004
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous determination of chloride and potassium in carbohydrate electrolyte beverages using an array of ion-selective electrodes controlled by a microcomputer

Abstract: Este trabalho descreve a elaboração de um sistema potenciométrico controlado por microcomputador para uso com um conjunto de eletrodos íon-seletivo. O sistema empregou uma placa de interface modelo ACL-8111 da ADLink Technology, para controlar a seleção dos eletrodos íon-seletivo, através de uma chave analógica (ADG201), com simultânea aquisição de dados. Um programa escrito na linguagem VISUAL BASIC 4.0 foi empregado para controle e aquisição de dado. Este sistema foi avaliado na determinação simultânea de cl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0
1

Year Published

2004
2004
2016
2016

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(6 citation statements)
references
References 12 publications
0
5
0
1
Order By: Relevance
“…The multiplexer is based on an acquisition card (model ACL‐8111 ADLink Technology) and an analogic switch (ADG201) with software written in VISUAL BASIC 4.0. Detailed architecture, schematics, and logical structure can be found in Reference 32.…”
Section: Methodsmentioning
confidence: 99%
“…The multiplexer is based on an acquisition card (model ACL‐8111 ADLink Technology) and an analogic switch (ADG201) with software written in VISUAL BASIC 4.0. Detailed architecture, schematics, and logical structure can be found in Reference 32.…”
Section: Methodsmentioning
confidence: 99%
“…The basic composition of coconut water replaces the electrolytes eliminated through sweat, such as: sodium, potassium, magnesium and calcium. The concentration of these electrolytes in this beverage, supplies an osmotic pressure similar to that observed in blood (Fernandes et al, 2000) in this way, it is very important to check the concentration of these electrolytes.…”
Section: Introductionmentioning
confidence: 75%
“…Software in VISUAL BASIC 4.0 was utilized for commutation of the electrodes. Both the computational system and the used software has been described in a previous work (Fernandes et al, 2000).…”
Section: Apparatusmentioning
confidence: 99%
“…Potentiometric cells with a pH single-rod measuring cell (HI-1131P model) or a homemade potassium ion selective electrode (ISE-K) were used for testing the allsolid-state reference electrodes in real samples for direct potentiometry. The ISE-K was prepared according to previous work (Fernandes et al, 2000).…”
Section: Instrumentation and Protocolsmentioning
confidence: 99%