Operational analysis and limitations of the VSI-Based multi-line FACTS controllers

Abstract: In this paper, the operational analysis and the main limitations of the VSI-based multi-line FACTS controllers, namely: the GIPFC (Generalized Interline Power Flow Controller) and the IPFC (Interline Power Flow Controller), are analyzed. The GIPFC & IPFC are amongst the newest devices within the FACTS technology. By utilizing these devices an enhanced and nearly instantaneous controllability over independent transmission systems, can be obtained. The steady-state analysis of a GIPFC & IPFC controlling two bala… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2013
2013
2013
2013

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(7 citation statements)
references
References 7 publications
(3 reference statements)
0
7
0
Order By: Relevance
“…Power electronics has revolutionised the use of phase shifters in power system control because the replacement of the traditional mechanical tap changers by thyristor valves (to obtain the thyristor-controlled PST or TCPST) has increased the response speed of phase shifters and made them effective for the enhancement of both small disturbance and transient stability (see [184,193,195,11,206] [193]. This element consists of two (or more) SSSCs [206] installed in two (or more) lines and connected at their DC terminals. Thus, in addition to serially compensate the reactive power, each SSSC can provide real power to the common DC link from its own line.…”
Section: Key Technologiesmentioning
confidence: 99%
See 4 more Smart Citations
“…Power electronics has revolutionised the use of phase shifters in power system control because the replacement of the traditional mechanical tap changers by thyristor valves (to obtain the thyristor-controlled PST or TCPST) has increased the response speed of phase shifters and made them effective for the enhancement of both small disturbance and transient stability (see [184,193,195,11,206] [193]. This element consists of two (or more) SSSCs [206] installed in two (or more) lines and connected at their DC terminals. Thus, in addition to serially compensate the reactive power, each SSSC can provide real power to the common DC link from its own line.…”
Section: Key Technologiesmentioning
confidence: 99%
“…The IPFC can be considered as a multiline FACTS device -UPFC is the most powerful and versatile FACTS device, able to independently and autonomously control voltage amplitude, and real and reactive power flow. This element consists of a shunt and a series transformer, which are connected via two VSCs, a STATCOM (converter 1 -for the shunt part) and SSSC (converter 2 -for the series part) [206], with a common DC link (capacitor).…”