1998
DOI: 10.1590/s0102-86501998000100001
|View full text |Cite
|
Sign up to set email alerts
|

Vaporizador artesanal de éter para cirurgia experimental em pequenos roedores

Abstract: O presente trabalho descreve modelo experimental de vaporizador artesanal de éter, modificado a partir do modelo de WAYNFORTH & FLECKNELL, a fim de manter fluxo contínuo e homogêneo do anestésico em cirurgias onde se utiliza roedores de pequeno porte como animais de experimentação. O sistema é construído a partir de material encontrado em casas de materiais para aquários, sonda e tubo de ensaio de uso hospitalar, base de madeira e campânula de vidro confeccionada em vidraçaria. Como vantagens do sistema po… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0
7

Year Published

2003
2003
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 17 publications
(18 citation statements)
references
References 0 publications
0
11
0
7
Order By: Relevance
“…In order to improve anesthesia performance and prevent problems such as air pollution, unstable anesthesia level and anesthetic wastefulness, an ether vapourizator for little rodents was used 9,10 . The median and left lateral lobes of the liver (corresponding to 67% of the organ) were excised 11 .…”
Section: Surgical Proceduresmentioning
confidence: 99%
“…In order to improve anesthesia performance and prevent problems such as air pollution, unstable anesthesia level and anesthetic wastefulness, an ether vapourizator for little rodents was used 9,10 . The median and left lateral lobes of the liver (corresponding to 67% of the organ) were excised 11 .…”
Section: Surgical Proceduresmentioning
confidence: 99%
“…The authors of the present study demonstrate modifications to the equipment that is described by Brito et al 2,4 , with the additional advantages of oxygen availability and better control of the flow of the anesthetic agent with minimal loss to room air, making the equipment more useful and practical.…”
Section: Introductionmentioning
confidence: 77%
“…Notwithstanding the great improvements made by Brito et al 2,4 in anesthetic equipment models for rats, the construction of this anesthetic equipment came from a need to resolve persistent problems with inhalation anesthesia 5 . This new method retains such advantages of Brito´s model 2,4 as low cost, ease of use, acceptable level of tracheobronchial secretions during induction, a small amount of anesthetic agent used and lost to the environment 5 .…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations