Derivative spectrophotometric method for determination of acyclovir in polymeric nanoparticles

Abstract: Recebido em 28/2/11; aceito em 13/6/11; publicado na web em 8/8/11A derivative spectrophotometric method was validated for quantification of acyclovir in poly (n-butylcyanoacrylate) (PBCA) nanoparticles. Specificity, linearity, precision, accuracy, recovery, detection (LOD) and quantification (LOQ) limits were established for method validation. First-derivative at 295.2 nm eliminated interferences from nanoparticle ingredients and presented linearity for acyclovir concentrations ranging from 1.25 to 40.0 µg/mL… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
4
0
4

Year Published

2014
2014
2020
2020

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 18 publications
(9 citation statements)
references
References 20 publications
1
4
0
4
Order By: Relevance
“…As seen in Fig.2A, and as previously reported in the literature 21,22,29 , one of the main problems with UV-Vis spectrophotometry when working with complex samples, such as guarana, is the superposition of bands (overlapping).…”
Section: Fig 2: Scanning Spectra Of Caffeine (Red) Catechin (Blue)supporting
confidence: 78%
“…As seen in Fig.2A, and as previously reported in the literature 21,22,29 , one of the main problems with UV-Vis spectrophotometry when working with complex samples, such as guarana, is the superposition of bands (overlapping).…”
Section: Fig 2: Scanning Spectra Of Caffeine (Red) Catechin (Blue)supporting
confidence: 78%
“…PBCA nanoparticles loaded with NFOH were obtained by emulsion polymerization as previously described (Tavares et al, 2011;Sham et al, 2004). Prof. Elizabeth Igne Ferreira, from FCF-USP (São Paulo, Brazil) provided hydroxymethylnitrofurazone from LAPEN (Laboratory of Design and Synthesis of Chemotherapeutic Agents Potentially Active on Neglected Diseases).…”
Section: Chemical and Reagentsmentioning
confidence: 99%
“…A espectrofotometria derivada (ED) é uma transformação matemática do espectro de ordem zero em um espectro em derivada (PASCHOAL et al, 2003, TAVARES et al, 2012, consiste na diferença da absorção (dA) versus variação do comprimento de onda (dλ) (CONSIGLIERI, 1992, DONATO et al, 2010. Portanto, a derivação do espectro não aumenta o conteúdo de informações da análise, uma vez que estas são as mesmas contidas no espectro de ordem zero, ela somente individualiza os constituintes, permitindo uma melhor visualização das pequenas características espectrais (DONATO et al, 2010, PASCHOAL et al, 2003.…”
Section: Resultsunclassified
“…A espectrofotometria derivada também pode ser mais sensível, em certas situações, como quando a banda é mais larga e menos aguda que seu interferente (CONSIGLIERI, et al, 2001, TAVARES et al, 2012. O aumento da seletividade deve-se à separação das bandas sobrepostas, enquanto que o aumento da sensibilidade é devido à amplificação do sinal da derivada e à diminuição do ruído (DONATO et al, 2010, PASCHOAL et al, 2003.…”
Section: Resultsunclassified
See 1 more Smart Citation