1998
DOI: 10.1590/s0100-40421998000400008
|View full text |Cite
|
Sign up to set email alerts
|

Comparação de dois tipos de amostragem de chuva: deposição total e deposição apenas úmida em àrea costeira tropical

Abstract: tropical coastal area. During 6 months the composition of rain samples collected simultaneously over 24h with an open collector and with an automatic opened collector (KFA -J¸lich Type) at 500m of the Atlantic coastline of Salvador were compared. All average concentrations were higher for the "total" samples than for the "wet only" samples, except for hydrogen ions, nitrate and ammonium.Keywords: total deposition; wet only deposition; rain sampling. ARTIGO INTRODUÇÃOAmostras de precipitação podem ser coletadas… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
6
0
9

Year Published

2005
2005
2016
2016

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(16 citation statements)
references
References 12 publications
(19 reference statements)
1
6
0
9
Order By: Relevance
“…A avaliação da qualidade dos resultados das análises das amostras de água de chuva foi feita com base na comparação da condutividade medida (k med ) e a condutividade calculada (k calc ) e no balanço de massa iônica equivalente (ΔIon), através das Equações 5 e 6 17 :…”
Section: Qualidade Analíticaunclassified
See 2 more Smart Citations
“…A avaliação da qualidade dos resultados das análises das amostras de água de chuva foi feita com base na comparação da condutividade medida (k med ) e a condutividade calculada (k calc ) e no balanço de massa iônica equivalente (ΔIon), através das Equações 5 e 6 17 :…”
Section: Qualidade Analíticaunclassified
“…De acordo com os critérios apresentados por Campos et al 17 , deverão ser rejeitadas amostras com k med ≤ 30 µS cm -1 cujos Δk excederem a faixa de ±30%, bem como aquelas com k med > 30 µS cm -1 cujos Δk excederem a faixa de ±50%. Da mesma forma, deverão ser rejeitadas amostras com I ≤ 100 µeq L -1 cujos ΔIon > ±50%, bem como aquelas com I > 100 µeq L -1 cujos ΔIon > ±25%.…”
Section: Qualidade Analíticaunclassified
See 1 more Smart Citation
“…According to Miglavacca et al (2005), concentrations of chemical elements in rainwater are influenced by anthropogenic factors, including: thermoelectric plants, ironworks, fertilizer plants and residue burning, in addition to natural factors (CAMPOS et al 1998) such as sea salt spray. Figure 5 illustrates the amount of ions (kg ha -1 ) contained in rainwater.…”
Section: Nutrient Contents In Rainwatermentioning
confidence: 99%
“…2,3 A remoção desses poluentes, ou espécies inorgânicas e orgânicas, do ar pode ocorrer através da precipitação atmosférica, úmida ou seca, tendo sua composição química avaliada por diversos estudos, nas últimas décadas. [4][5][6][7][8][9][10] Este trabalho teve por objetivo quantificar a precipitação úmida em três locais da Região Metropolitana de Porto Alegre (RMPA) através da análise de íons majoritários e elementos metálicos, bem como identificar as principais fontes de contaminação através da análise estatística multivaraiada, análise de componentes principais e cluster.…”
Section: Introductionunclassified