2012
DOI: 10.1590/s0100-39842012000300001
|View full text |Cite
|
Sign up to set email alerts
|

Contrastes orais neutros para enterografia por tomografia computadorizada

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0
2

Year Published

2013
2013
2019
2019

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 9 publications
0
1
0
2
Order By: Relevance
“…With the utilization of any protocol (three or four phases), one observes a mean dose reduction per scan equivalent to the effective dose of 12.5 mSv, because of the suppression of the acquisition phase without intravenous contrast agent injection. The management of the radiation dose by means of a judicious utilization of the different acquisition phases in protocols of abdominal CT has been the object of several recently published studies (34,35) . The number of patients evaluated in HCC investigation (19 patients) could have been higher, but it was enough to verify, by means of statistical tests, that there was no impact in suppressing the non-contrastenhanced phase, as other studies have already suggested 8) .…”
Section: Discussionmentioning
confidence: 99%
“…With the utilization of any protocol (three or four phases), one observes a mean dose reduction per scan equivalent to the effective dose of 12.5 mSv, because of the suppression of the acquisition phase without intravenous contrast agent injection. The management of the radiation dose by means of a judicious utilization of the different acquisition phases in protocols of abdominal CT has been the object of several recently published studies (34,35) . The number of patients evaluated in HCC investigation (19 patients) could have been higher, but it was enough to verify, by means of statistical tests, that there was no impact in suppressing the non-contrastenhanced phase, as other studies have already suggested 8) .…”
Section: Discussionmentioning
confidence: 99%
“…Além disso, a RNM permitiu melhor embasamento da escolha terapêutica em mais de 50% dos casos (MORAES, 2016, p. 40).  Apesar da ampla aplicabilidade e de ótimos resultados da entero-TC, este método tem como principal desvantagem autilização da radiação ionizante, o que limita muitas vezes a indicação a crianças e até mesmo para adultos devido a necessidade de repetição do exame ao longo da vida (AZEVEDO et al, 2014;BURLIN et al, 2017;COSTA-SILVA;MARTINS;PASSOS, 2010;D'IPPOLITO et al, 2012;GOMES, 2016;MARMO, 2017;MATOS et al, 2012;PARENTE, 2012;RENOSTO, 2017;RODRIGO, 2013;TORRÃO et al, 2012).…”
Section: Enterografia Por Ressonância Magnética (Entero-rm)unclassified
“… A principal e maior vantagem desse exame é a não utilização de radiação ionizante, podendo ser repetida múltiplas vezes sem prejuízo ao paciente (AZEVEDO et al, 2014;BURLIN et al, 2017;MATOS et al, 2012;MISZPUTEN, 2013;MORAES, 2016;PARENTE, 2012;RODRIGO, 2013);  Apresenta melhor contraste tecidual (MATOS et al, 2012;TORRÃO et al,  Principal utilização na fase aguda (BURLIN et al, 2017).…”
Section: Da Enterografia Por Ressonância Magnética (Entero-rm) A) Vanunclassified