2011
DOI: 10.1590/s0004-27492011000200006
|View full text |Cite
|
Sign up to set email alerts
|

Aplicação de fórmula corretiva nas alterações da pressão intraocular dos pacientes submetidos a LASIK

Abstract: RESUMOObjetivo: Comparar a pressão intraocular (PIO) pré e pós-LASIK, correlacionando-as com as mudanças da espessura corneana central (ECC) e ceratometria simulada média (K), assim como verificar o resultado de fórmula corretiva proposta anteriormente. Métodos: Estudo longitudinal, prospectivo, realizado em pacientes submetidos a LASIK. Os pacientes foram submetidos ao exame oftalmológico completo, no pré-operatório e após 2 meses da cirurgia. A pressão intraocular foi avaliada com tonô-metro de aplanação de … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
3
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 9 publications
1
3
0
Order By: Relevance
“…This is consistent with a study performed by Silva et al in 2011, which found a weak correlation between average simulated keratometry and change in IOP readings. 21 Our result is also consistent with a study by Yin Lin et al that explored the factors that may alter IOP measurements following LASIK. These authors reported that CCT and central ablation depth are the main parameters to be considered.…”
Section: Discussionsupporting
confidence: 92%
“…This is consistent with a study performed by Silva et al in 2011, which found a weak correlation between average simulated keratometry and change in IOP readings. 21 Our result is also consistent with a study by Yin Lin et al that explored the factors that may alter IOP measurements following LASIK. These authors reported that CCT and central ablation depth are the main parameters to be considered.…”
Section: Discussionsupporting
confidence: 92%
“…Previously, large quantities of formulas have been raised to correct IOP values following corneal refractive surgeries [9–11]. However, various confounding factors including surgical designs (i.e., flap thickness, residual stromal bed thickness, optic zone diameter and ablation depth), individual differences (i.e., age, gender, race, refractions, corneal curvature corneal hydration and post-operative wound healing response) [12] and long-term postoperative topical steroid usage make these formulas widely divergent.…”
Section: Introductionmentioning
confidence: 99%
“…This is a critical factor in ablative corneal refractive surgery, which, along with other biomechanical changes induced by the procedure, affects the measurement of the IOP after the procedure. The underestimation of IOP after photorefractive surgery using Goldmann applanation tonometry, has been documented in many studies [17,[18][19][20]23,24,[27][28][29]31,32,[35][36][37][38].…”
Section: Patients With History Of Corneal Refractive Surgery With Exc...mentioning
confidence: 98%
“…Secondarily, it alters the precision of the IOP measurement, especially with applanation tonometers. Goldman tonometry has been widely shown to underestimate IOP after corneal photorefractive surgery [17,19,[20][21][22][23][24][25][26][27][28][29][30][31][32][33][34][35][36][37][38]. This underestimation of IOP may at some point delay the diagnosis of de novo glaucoma in patients with a history of refractive surgery [39][40][41][42][43][44].…”
Section: Introductionmentioning
confidence: 99%