Comparison the monitoring data of an on-site stormwater detention (OSD) and the results in the use of theoretical methods for its design

Abstract: On-site stormwater detention – OSD has been constructed in big Brazilian cities, as a way to reduce the impact of urbanization on the drainage system. However, there are a few studies about its efficiency in real scale. This article aims to compare the monitoring data of an OSD built in a hospital in Belo Horizonte and the results determined by theoretical methods, commonly used in the design of this structure. Inside the OSD was installed a level sensor to monitor water level during rain events. The data was … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
3
0
1

Year Published

2019
2019
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 4 publications
1
3
0
1
Order By: Relevance
“…Improvement is needed to lower the field dataset so that no near or exceeding of maximum tank capacity to occur. This observation is similar to the finding of [15] that stresses the importance of field monitoring to validate the design data.…”
Section: Figure 6 Detention Volumes According To Observed Rainfall Dsupporting
confidence: 89%
“…Improvement is needed to lower the field dataset so that no near or exceeding of maximum tank capacity to occur. This observation is similar to the finding of [15] that stresses the importance of field monitoring to validate the design data.…”
Section: Figure 6 Detention Volumes According To Observed Rainfall Dsupporting
confidence: 89%
“…In other studies Drumond et al [17], they conducted research on the water flow characteristics in an urban system in which on-site reservoirs were used. They showed that the analyses based on the common rational method differ significantly from the real flows in systems containing this type of devices.…”
Section: Introductionmentioning
confidence: 99%
“…Piel et al (1999) have found that the lack of maintenance is the main cause for low performance of OSD. Drumond et al (2018) monitored two OSDs built in Belo Horizonte and compared the maximum water levels data with theoretical simulations. The results showed that theoretical simulations presented lower values than those monitored.…”