2019
DOI: 10.1590/1809-2950/18032726022019
|View full text |Cite
|
Sign up to set email alerts
|

Laser Photobiomodulation in the acute inflammatory response of the calcaneal tendon injury in rats exposed to cigarette smoke

Abstract: Nicotine delays the healing process and increases the levels of myeloperoxidase (MPO), an enzyme that plays a key role in the production of reactive oxygen species during the inflammatory process. Laser Photobiomodulation (PBM) is one of the most used electrophysical agents in the treatment of the calcaneal tendon, however, its effects on MPO activity need to be further elucidated. This study aimed to evaluate the effects of laser PBM on MPO activity after inflicting an injury to the calcaneal tendon of rats e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0
1

Year Published

2021
2021
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 35 publications
(41 reference statements)
0
1
0
1
Order By: Relevance
“…Observou-se nessa revisão uma diferença na densidade de energia utilizada, bem como na frequência de utilização e na potência. Densidades de energia variaram de 1 a 20 J/cm 2 , sendo a mais utilizada a de 4J/cm 2 (Barbosa et al, 2020;Feitosa et al, 2015;Cunha et al, 2019;Taradaj et al 2018), 5J/cm 2 (Atasoy et al, 2017;Sousa et al, 2015;Cunha et al, 2019) (Nilforoushzadeh et al, 2019;Fioruzi et al, 2018;, 2J/cm 2 (Martins et al, 2015), 3J/cm 2 (Scherer et al 2019;De Souza et al, 2018), 0,25 J/cm 2 (Barbosa et al, 2020), 10 J/cm 2 e 20 J/cm 2 (Atasoy et al, 2017) e 8J/cm 2 ( Sousa et al, 2015). Observou-se, quanto aos parâmetros de aplicação da FBM, que eles variaram de 632,8 a 940 nm, mas a maior parte dos estudos (12= 75%) utilizou entre 632,8 a 670 nm, demonstrando uma padronização na utilização nas feridas.…”
Section: Discussionunclassified
“…Observou-se nessa revisão uma diferença na densidade de energia utilizada, bem como na frequência de utilização e na potência. Densidades de energia variaram de 1 a 20 J/cm 2 , sendo a mais utilizada a de 4J/cm 2 (Barbosa et al, 2020;Feitosa et al, 2015;Cunha et al, 2019;Taradaj et al 2018), 5J/cm 2 (Atasoy et al, 2017;Sousa et al, 2015;Cunha et al, 2019) (Nilforoushzadeh et al, 2019;Fioruzi et al, 2018;, 2J/cm 2 (Martins et al, 2015), 3J/cm 2 (Scherer et al 2019;De Souza et al, 2018), 0,25 J/cm 2 (Barbosa et al, 2020), 10 J/cm 2 e 20 J/cm 2 (Atasoy et al, 2017) e 8J/cm 2 ( Sousa et al, 2015). Observou-se, quanto aos parâmetros de aplicação da FBM, que eles variaram de 632,8 a 940 nm, mas a maior parte dos estudos (12= 75%) utilizou entre 632,8 a 670 nm, demonstrando uma padronização na utilização nas feridas.…”
Section: Discussionunclassified
“…[40][41][42] Besides, researchers also pay attention to the second harmonic generation (SHG) characteristics of noble metal nanomaterials, which could be widely used in laser devices, biology, and other fields. [43][44][45][46][47][48] In general, asymmetric metal nanostructures can produce strong SHG signals. Li et al reported that the SHG is caused by the anisotropy of the Au nanorods.…”
Section: Introductionmentioning
confidence: 99%