2022
DOI: 10.1590/1806-9282.20220498
|View full text |Cite
|
Sign up to set email alerts
|

Apropos of quality for fine-needle aspiration cytology of thyroid nodules with 22-, 23-, 25-, even 27-gauge needles and indeterminate cytology in thyroidology: an aide memory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 13 publications
0
6
0
Order By: Relevance
“…Debate is still ongoing on an optimal needle size for thyroid FNA cytology in thyroidology. In this sense, we reported a favorable non-diagnostic cytology rate on a sum of 500 nodules in 425 eligible consecutive outpatients during 38 months, involving ultrasonography (US)-guided FNA with a surgeon-performed US (SUS) in thyroid nodules with 27-G fine needles [5][6][7][8][9][10][11][12] . Therefore, would the outcomes of the study at that point be altered as they had harnessed significantly (i) finer or (ii) larger needle sizes?…”
Section: Re: "American Thyroid Association and Thyroid Imaging Report...mentioning
confidence: 99%
“…Debate is still ongoing on an optimal needle size for thyroid FNA cytology in thyroidology. In this sense, we reported a favorable non-diagnostic cytology rate on a sum of 500 nodules in 425 eligible consecutive outpatients during 38 months, involving ultrasonography (US)-guided FNA with a surgeon-performed US (SUS) in thyroid nodules with 27-G fine needles [5][6][7][8][9][10][11][12] . Therefore, would the outcomes of the study at that point be altered as they had harnessed significantly (i) finer or (ii) larger needle sizes?…”
Section: Re: "American Thyroid Association and Thyroid Imaging Report...mentioning
confidence: 99%
“…Demet Sengul 1 * , Ilker Sengul 2,3 Dear Editor, Mater artium necessitas. A Deucalione (Necessity is the mother of invention.…”
Section: A Vignette Epexegesis Of a Model For Training Sonography-gui...mentioning
confidence: 99%
“…Of note, the debate is still ongoing on this controversial issue utilizing a broad range, from 21 to 27 gauges, of needle sizes 2 , 3 , 4 . Luz et al 1 emphasized using a 25-gauge needle, without the puncture guide, in their good work.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Undoubtedly, indeterminate cytology was highlighted as a subdivision needing urgently addressed [7][8][9]. Subdivision of intermediate suspicion is crucial for effective FNA and the size of the fine needle, which could decrease the implied ROM [10,11].…”
Section: Introductionmentioning
confidence: 99%