2016
DOI: 10.1590/1414-431x20165200
|View full text |Cite
|
Sign up to set email alerts
|

Oxygen uptake, respiratory exchange ratio, or total distance: a comparison of methods to equalize exercise volume in Wistar rats

Abstract: This study compared strategies to equalize the volume of aerobic exercise performed with different intensities by Wistar rats, based on the distance covered during exercise bouts and energy expenditure (EE, isocaloric sessions) obtained from oxygen uptake (V̇O2) or respiratory exchange ratio (RER). Thirty-three male rats (270.5±12.8 g) underwent maximal exercise tests to determine V̇O2 reserve (V̇O2R), being randomly assigned to three groups: moderate-intensity continuous exercise at speed corresponding to 50%… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 38 publications
0
7
0
Order By: Relevance
“…The gas analyzer continuously measured relative concentrations of oxygen (O 2 ) and carbon dioxide (CO 2 ) effluent in the chamber. The VO 2 was calculated by specific software (Metabolism™, Panlab Harvard Apparatus, Barcelona, Spain) using equations described elsewhere [20]. Standard conditions of temperature, pressure and humidity ( STPD ) were kept in all experiments.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The gas analyzer continuously measured relative concentrations of oxygen (O 2 ) and carbon dioxide (CO 2 ) effluent in the chamber. The VO 2 was calculated by specific software (Metabolism™, Panlab Harvard Apparatus, Barcelona, Spain) using equations described elsewhere [20]. Standard conditions of temperature, pressure and humidity ( STPD ) were kept in all experiments.…”
Section: Methodsmentioning
confidence: 99%
“…The testing protocol consisted of load increments of 8 cm/s every 3 min, until the rats were no longer able to run. Exhaustion was determined when animals remained at the end of treadmill (electrical shock grid) for 5 seconds and VO 2peak corresponded to the highest VO 2 obtained during the test [20].…”
Section: Methodsmentioning
confidence: 99%
“…The gas analyzer continuously measured relative concentrations of oxygen (O 2 ) and carbon dioxide (CO 2 ) effluent in the chamber. The VO 2 was calculated by specific software (Metabolism TM , Panlab Harvard Apparatus, Barcelona, Spain) using equations described elsewhere [20]. Standard conditions of temperature, pressure and humidity (STPD) were kept in all experiments.…”
Section: Maximal Graded Exercise Testingmentioning
confidence: 99%
“…The testing protocol consisted of load increments of 8 cm/s every 3 min, until the rats were no longer able to run. Exhaustion was determined when animals remained at the end of the treadmill (electrical shock grid) for 5 seconds and VO 2peak corresponded to the highest VO 2 obtained during the test [20]. The shock grid delivered very low electrical currents (0.2 mA) and was used only to induce the rats to run.…”
Section: Maximal Graded Exercise Testingmentioning
confidence: 99%
See 1 more Smart Citation