2016
DOI: 10.1177/2326409816669370
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of the Genetic Screening Processor for the Performance of Newborn Screening Tests

Abstract: The collection of dried blood spots (DBSs) on filter paper has been a powerful tool in newborn screening (NBS) programs and in other fields. However, filter paper has been associated with some level of imprecision due to the filter paper matrix effect. In order to minimize measurement variations, these interferences should be evaluated by NBS assays. The aim of this study is to evaluate the performance of genetic screening processor (GSP) equipment in comparison with a widely used AutoDELFIA and to discuss the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0
1

Year Published

2021
2021
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 8 publications
(20 reference statements)
0
1
0
1
Order By: Relevance
“…Firstly, the AutoDelfia and GSP instruments are not directly comparable when measuring DBS TSH, as previous studies have shown that the GSP assay has a negative bias of around 10%-20%, when compared to the AutoDelfia assay. 22,23 Secondly, serum/ plasma TSH assays are not always comparable across different platforms and the level of comparability also changes over time with the release of new reagent and calibrator lots. Thirdly, the haematocrit of the blood (as discussed above), the volume of blood used and the punch location, all influence the final DBS TSH result.…”
Section: Discussionmentioning
confidence: 99%
“…Firstly, the AutoDelfia and GSP instruments are not directly comparable when measuring DBS TSH, as previous studies have shown that the GSP assay has a negative bias of around 10%-20%, when compared to the AutoDelfia assay. 22,23 Secondly, serum/ plasma TSH assays are not always comparable across different platforms and the level of comparability also changes over time with the release of new reagent and calibrator lots. Thirdly, the haematocrit of the blood (as discussed above), the volume of blood used and the punch location, all influence the final DBS TSH result.…”
Section: Discussionmentioning
confidence: 99%
“…De Castro 等 [9] 应用 GSP 分析仪检测促甲状腺 激素、17-羟孕酮和免疫反应性胰蛋白酶相应试剂 盒的低、高质控品,显示批内和批间精密度分别为 6.0%~14.2%和 4.4%~13.9%;Fingerhut 等 [8] 应用 GSP 分析仪检测促甲状腺激素、17-羟孕酮、免疫反 应性胰蛋白酶、总 T4 和半乳糖-1-磷酸尿苷转移酶 活性相应试剂盒的低、高质控品,显示批内和批间 精密度分别为 2.5%~8.9%和 5.7%~11.0%,平均 回收率为 97.8%~107.1%;国内对苯丙氨酸的检 测发现,美国疾病预防控制中心质控品检测值与 靶值的相对偏倚为-6.7%~19.2%,低、高质控品总 变异系数分别为 7.5%和 7.4% [10] 。上述研究结果 表明,GSP 分析仪精密度和准确度较高,检测值稳 定。GSP 分析仪与 1420 分析仪同步检测临床 G6PD 确诊样本,检测值一致性较高 [11] 。本研究 好的预防作用 [17][18] 。Ainoon 等 [19] 采用半定量荧 光斑点法和定量法同步检测 G6PD,两种方法的疾…”
Section: 提高了新生儿疾病筛查的效率。unclassified