This paper provides how to solve the problems analytically and experimentally that occur for testing the water injection pump under development. First of all, water injection pump, based on shaft system dynamic analysis, is verified by measuring the behavior of the shaft system. After the water injection pump is measured, the structural resonances which can cause excessive noise, degradation the equipment life and malfunction are found. Therefore, by changing the structural design, the resonance should be avoided. Application of the design variables to the experimentally resonance avoidance is difficult. So analytically, with application of the design variables, the design will be changed with mode analysis using FEM. Fig. 1의 (a)와 같이 모터의 동력이 증 속기를 거쳐 Fig. 1(b)의 축으로 전달되며 6000 rpm †
연구 모델의 동특성 분석
연구 모델은
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.