Zinc oxide due to specific electrical, optical and acoustic properties is the important semiconductor material, which has many various applications. There is growing interest in ZnO due to its potential applicability for optoelectronic devices such as light-emitting diodes, laser diodes and detectors for UV wavelength range. ZnO properties are very close to those of widely recognized semiconductor GaN. The band gap of ZnO (3.37 eV) is close to that of GaN (3.39 eV) but ZnO exciton binding energy (60 meV) is twice larger than that of GaN (28 meV). Optically pumped UV lasing have been demonstrated at room temperature using high textured ZnO films. The excitonic gain close to 300 cm -1 was achieved. ZnO thin films are expected to have higher quantum efficiency in UV semiconductor laser than GaN. The physical properties of ZnO are considered. PEMOCVD technology was used to deposit piezoelectric and highly transparent electroconductive ZnO films. Their properties are discussed. The experiments on polycrystalline ZnO films deposited by RF magnetron sputtering at different partial pressure of oxygen are presented. AFM images were studied in tapping mode for deposited films. The investigated films were dielectric ones and had optical transparency within 65-85% at thickness in the interval 0.2-0.6 µm.
A fluorescence polarization immunoassay (FPIA) based on a monoclonal antibody for the detection of parathion-methyl (PM) was developed and optimized. Fluorescein-labeled PM derivatives (tracers) with different structures were synthesized and purified by thin-layer chromatography. The influence of immunogen and tracer structures on the assay characteristics was investigated. PM concentration determinable by the FPIA ranged from 25 to 10000 ppb. The detection limit was 15 ppb. Methanol extracts of vegetable, fruit, and soil samples were diluted 1/10 for the analysis. Recovery in spiked samples averaged between 85 and 110%. The method developed is characterized by high specificity and reproducibility (CV ranged from 1.5 to 9.1% for interassay and from 1.8 to 14.1% for intra-assay). The FPIA method can be applied to the screening of food and environmental samples for PM residues without complicated cleanup.
To identify the explosive used in a terrorist attack, or to obtain an early sign of environmental pollution it is important to use simple and rapid assays able to detect analytes at low levels, possibly on-site. This is particularly true for TNT (2,4,6-trinitrotoluene), one of the most employed explosives in the 20th century and at the same time, because of its toxicity, a well known pollutant. In this work we describe the development of an indirect competitive ELISA with chemiluminescent detection (CL-ELISA) and of a lateral-flow immunoassay (LFIA) based on colloidal gold nanoparticle labels. A commercially available monoclonal antibody was used and 13 specially synthesized conjugates were tested. We optimized the assay by determining the optimal concentration of monoclonal antibody and conjugates and the influence of various non-specific factors such as: tolerance to organic solvents at different concentrations, the washing and competitive step time, and the cross-reactivity with related compounds. The sensitivity and reproducibility of the CL-ELISA were good (LOD and IC(50) values in the ng mL(-1) range, and CV value about 7%). It has been applied to real samples of various materials involved in a controlled explosion of an "improvised explosive device". Three extraction procedures were tested on these samples, all employing methanol as the solvent. The lateral flow immunoassay (LFIA), developed by using the same immunoreagents, reached a detection limit of 1 microg mL(-1) when tested on the same samples analysed by CL-ELISA.
Purpose. The results of cryoballoon ablation (CBA) procedure have been mainly derived from studies conducted in experienced atrial fibrillation (AF) ablation centres. Here, we report on CBA efficacy and complications resulting from real practice of this procedure at both high- and low-volume centres. Methods. Among 62 Russian centres performing AF ablation, 15 (24%) used CBA technology for pulmonary vein isolation. The centres were asked to provide a detailed description of all CBA procedures performed and complications, if encountered. Results. Thirteen sites completed interviews on all CBAs in their centres (>95% of CBAs in Russia). Six sites were high-volume AF ablation (>100 AF cases/year) centres, and 7 were low-volume AF ablation. There was no statistical difference in arrhythmia-free rates between high- and low-volume centres (64.6 versus 60.8% at 6 months). Major complications developed in 1.5% of patients and were equally distributed between high- and low-volume centres. Minor procedure-related events were encountered in 8% of patients and were more prevalent in high-volume centres. Total event and vascular access site event rates were higher in women than in men. Conclusions. CBA has an acceptable efficacy profile in real practice. In less experienced AF ablation centres, the major complication rate is equal to that in high-volume centres.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.