The features of the state investigation of a flowing liquid by nuclear magnetic resonance was defined. The methodology for the state investigation of the flowing medium by changing the values of the longitudinal T1 and transverse T2 relaxation times is justified. For the parameters of the registration system of the signal of nuclear magnetic resonance and magnetic fields are established relations between them. The implementation of these ratios allows to obtain a signal to noise ratio of more than 5 for carrying out measurements of T1 and T2 values in real time with an error not exceeding 1%. The results of experimental research are presented.
Рассмотрены особенности регистрации сигналов ядерного магнитного резонанса в слабом магнитном поле от малого объема исследуемой среды. Учет установленных нами особенностей в новой разработанной конструкции магнитной системы для малогабаритного ядерно-магнитного спектрометра, а также в методике регистрации сигнала ЯМР позволяет значительно расширить возможности применения явления ядерного магнитного резонанса для исследования конденсированных сред в экспресс-режиме. Представлены результаты экспериментальных исследований различных сред. DOI: 10.21883/PJTF.2017.13.44809.16654
Предложена новая модель описания структуры линии сигнала ядерного магнитного резонанса, регистрируемого в слабом магнитном поле от конденси-рованной среды. Представлены результаты и сследований формы линии сигнала ядерного магнитного резонанса, регистрируемого с использованием модуляци-онной методики в слабом магнитном поле от малого объема конденсированной среды. Разработана новая методика определения в экспресс-режиме состава смеси конденсированной среды и относительных концентраций ее компонентов.
The necessity of simultaneous measurement of the longitudinal T1 and transverse T2 relaxation times for monitoring the state of the flowing liquid during the study in the range of flow rate q changes by at least two orders of magnitude has been substantiated. A new method for measuring T1 has been developed. For its implementation, the design of a differential nuclear magnetic spectrometer has been proposed, which makes it possible to measure T1 in the entire range of measurement of flow rate q. The results of experimental studies are presented.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.