In a pilot-scale internal loop airlift reactor with a height of 5.5 m and a main column diameter of 0.484 m, the influence of three gas sparger structures (ladder distributor, tri-nozzle sparger and perforated plate) on the volumetric mass transfer coefficient kLa was investigated. It was found that the perforated plate produces the highest gas holdup difference and circulating liquid velocity between the riser and the downcomer. The perforated plate provides the most efficient mass transfer due to the more uniform gas distribution and higher circulating liquid velocity, followed by the ladder distributor and tri-nozzle spargers. Compared with the tri-nozzle sparger, the perforated plate increases the value of kLa by up to 16% at a superficial velocity of 0.15 m/s. Interestingly, the analysis of the liquid-phase mass transfer coefficient kL and specific area a with respect to gas velocity shows that the mass transfer rate is primarily controlled by a. By comparing the predictions of different mass transfer models, the slip velocity model based on penetration theory yields a satisfactory agreement with the experimental results within ±15% error. Meanwhile, empirical correlations regarding gas holdup and kLa were developed and were found to have good consistency with experimental values.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.