This paper presents the experimental results of axial compression tests on concrete-filled bimetallic tubes (CFBT). The cross section of the bimetallic tube is composed of an outer layer made of stainless steel and an inner layer made of carbon steel. A total of 12 specimens with a circular cross section were tested under axial compression. The test parameters included the thickness of the stainless steel tube layer (t ss =0-1.36 mm) and the compressive strength of the infilled concrete (f cu =21.1-42.8 MPa). Test results showed that, the two layers of the bimetallic tube worked well together, and the CFBT specimens exhibited ductile characteristics. The influence of the parameters on the failure mode, load versus deformation relationship, axial compressive strength, and strain development of the tested specimens were investigated. Finally, the feasibility of three existing design codes for predicting the axial compressive strength of CFST under axial compression was evaluated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.