• DWI-derived parameters from different models are capable of providing different pathophysiological information. • DWI, DKI and IVIM parameters are associated with Ki-67 proliferation status. • K derived from DKI is the strongest independent factor for the prediction of Ki-67 proliferation status.
A novel radar high-resolution range profile (HRRP) target recognition method based on a stacked autoencoder (SAE) and extreme learning machine (ELM) is presented in this paper. As a key component of deep structure, the SAE does not only learn features by making use of data, it also obtains feature expressions at different levels of data. However, with the deep structure, it is hard to achieve good generalization performance with a fast learning speed. ELM, as a new learning algorithm for single hidden layer feedforward neural networks (SLFNs), has attracted great interest from various fields for its fast learning speed and good generalization performance. However, ELM needs more hidden nodes than conventional tuning-based learning algorithms due to the random set of input weights and hidden biases. In addition, the existing ELM methods cannot utilize the class information of targets well. To solve this problem, a regularized ELM method based on the class information of the target is proposed. In this paper, SAE and the regularized ELM are combined to make full use of their advantages and make up for each of their shortcomings. The effectiveness of the proposed method is demonstrated by experiments with measured radar HRRP data. The experimental results show that the proposed method can achieve good performance in the two aspects of real-time and accuracy, especially when only a few training samples are available.
Background: Based on its high resolution in soft tissue, MRI, especially diffusion-weighted imaging (DWI), is increasingly important in the evaluation of cholesteatoma. The purpose of this study was to evaluate the role of the 2D turbo gradient-and spin-echo (TGSE) diffusion-weighted (DW) pulse sequence with the BLADE trajectory technique in the diagnosis of cholesteatoma at 3 T and to qualitatively and quantitatively compare image quality between the TGSE BLADE and RESOLVE methods. Method: A total of 42 patients (23 males, 19 females; age range, 7-65 years; mean, 40.1 years) with surgically confirmed cholesteatoma in the middle ear were enrolled in this study. All patients underwent DWI (both a prototype TGSE BLADE DWI sequence and the RESOLVE DWI sequence) using a 3-T scanner with a 64-channel brain coil. Qualitative imaging parameters (imaging sharpness, geometric distortion, ghosting artifacts, and overall imaging quality) and quantitative imaging parameters (apparent diffusion coefficient [ADC], signal-to-noise ratio [SNR], contrast, and contrast-to-noise ratio [CNR]) were assessed for the two diffusion acquisition techniques by two independent radiologists. Result: A comparison of qualitative scores indicated that TGSE BLADE DWI produced less geometric distortion, fewer ghosting artifacts (P < 0.001) and higher image quality (P < 0.001) than were observed for RESOLVE DWI. A comparison of the evaluated quantitative image parameters between TGSE and RESOLVE showed that TGSE BLADE DWI produced a significantly lower SNR (P < 0.001) and higher parameter values (both contrast and CNR (P < 0.001)) than were found for RESOLVE DWI. The ADC (P < 0.001) was significantly lower for TGSE BLADE DWI (0.763 × 10 − 3 mm 2 /s) than RESOLVE DWI (0.928 × 10 − 3 mm 2 /s). Conclusion: Compared with RESOLVE DWI, TGSE BLADE DWI significantly improved the image quality of cholesteatoma by reducing magnetic sensitive artifacts, distortion, and blurring. TGSE BLADE DWI is more valuable than RESOLVE DWI for the diagnosis of small-sized (2 mm) cholesteatoma lesions. However, TGSE BLADE DWI also has some disadvantages: the whole image intensity is slightly low, so that the anatomical details of the air-bone interface are not shown well, and this shortcoming should be improved in the future.
BackgroundDiffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) values as imaging biomarkers of rectal cancer are currently a hot research spot. The use of ADC values for preoperative judgment of pathological features in rectal cancer has been generally accepted. The image quality evaluation of conventional diffusion is severe deformation, and the measurement of ADC values can easily lead to bias. Readout-segmented echo-planar diffusion-weighted imaging (RESOLVE) provides high signal-to-noise ratio images and significantly reduces distortions caused by magnetosensitive effects. The purpose of this study was to explore the correlations between ADC values of RESOLVE and pathological prognostic factors in rectal adenocarcinoma.MethodsWe collected pathological data of 89 patients with pathologically confirmed rectal adenocarcinoma who directly underwent surgical resection without receiving adjuvant therapy. The patients were grouped according to the pathologic type, gross classification, degree of differentiation, TN stage, and immunohistochemical expression of epidermal growth factor receptor (EGFR).ResultsRESOLVE ADC values of rectal cancer were measured at b = 800, and correlations between the RESOLVE ADC values obtained in different groups were analysed. We found that RESOLVE ADC values in the ulcer-type group were significantly higher than those in the eminence-type group.ConclusionRESOLVE ADC values in different pathologic types of rectal cancer were significantly different. RESOLVE ADC values in the EGFR-positive group were significantly lower than those in the EGFR-negative group. There was no significant difference in RESOLVE ADC values between different degrees of pathologic differentiation, TN stages, and positive or negative lymph nodes. The quantitative description of RESOLVE ADC values could be used to assess the biological behaviour of rectal adenocarcinoma.
Design approach of a novel, triple‐mode wideband slotline antenna is proposed and studied. The proposed antenna is realised and implemented by employing the multiple resonant modes within a narrow slotline radiator, rather than utilising the traveling‐wave effect. At first, a triple‐digit, fork‐like microstrip tuning stub is used to excite the first and the second odd‐order mode within a slim, 3/2‐wavelength slotline radiator. Then, a pair of slotline stubs is introduced near the E‐field nulls of the third odd‐order mode. By finely tuning the parameters of the microstrip/slotline stubs, the three radiation modes are perturbed and merged to generate a wideband, radiation characteristic with three resonances. Prototype antennas are then fabricated and measured. Finally, the design approach is experimentally validated. It is shown that the proposed antenna's radiation bandwidth has been effectively increased to 33.2% while keeping a single, basic‐form narrow slotline radiator with a simple, non‐traveling‐wave configuration.
For a non-relativistic particle that freely moves on a curved surface, the fundamental commutation relations between positions and momenta are insufficient to uniquely determine the operator form of the momenta. With introduction of more commutation relations between positions and Hamiltonian and those between momenta and Hamiltonian, our recent sequential studies imply that the Cartesian system of coordinates is physically preferable, consistent with Dirac's observation. In present paper, we study quantization problem of the motion constrained on the two-dimensional sphere and develop a discriminant that can be used to show how the quantization within the intrinsic geometry is improper. Two kinds of parameterization of the spherical surface are explicitly invoked to investigate the quantization problem within the intrinsic geometry.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.