This workshop initiated a standardization process for extraction of cff DNA in maternal plasma. The highest yield was obtained by the QIAamp DSP Virus Kit, a result that will be evaluated in more detail in future studies.
One-step, quantitative and rapid detection of microRNA (miRNA) in tumor cells or tissues can provide critical information for clinical diagnosis and cancer treatment. In this work, we develop a magnetic relaxation switch sensing (MRS)-based miRNA sensor using magnetic microparticle (1 μm in diameter, MM1000)-DNA probe-magnetic nanoparticle (30 nm in diameter, MN30) conjugates (MM1000-DNA-MN30). In the presence of target miRNA, DSN enzyme selectively cleaves the DNA tether after miRNA/DNA hybridization to release MN30 and leaves the miRNA intact to lead to the declustering of more MN30 than before. In contrast to conventional MRS by measuring the change of transverse relaxation time (ΔT2) induced by the aggregation or dissociation of magnetic particles in the presence of target, we use the cleaved MN30 from conjugates as the direct readout of ΔT2, which is more sensitive and stable. This MRS-based assay allows for one-step detection of 5 fM of miR-21 in urine samples, quantification of miR-21 from 100 cancer cells, and differentiation of the expression of miR-21 in tumor and surrounding tissues. The merits of this assay, rapidity, ability for quantitation, high sensitivity, and one-step operation, ensure a promising future in diagnostic technology.
Background COVID-19 has caused a global pandemic and the death toll is increasing. However, there is no definitive information regarding the type of clinical specimens that is the best for SARS-CoV-2 detection, the antibody levels in patients with different duration of disease, and the relationship between antibody level and viral load. Methods Nasopharyngeal swabs, anal swabs, saliva, blood, and urine specimens were collected from patients with a course of disease ranging from 7 to 69 days. Viral load in different specimen types was measured using droplet digital PCR (ddPCR). Meanwhile, anti-nucleocapsid protein (anti-N) IgM and IgG antibodies and anti-spike protein receptor-binding domain (anti-S-RBD) IgG antibody in all serum samples were tested using ELISA. Results The positive detection rate in nasopharyngeal swab was the highest (54.05%), followed by anal swab (24.32%), and the positive detection rate in saliva, blood, and urine was 16.22%, 10.81%, and 5.41%, respectively. However, some patients with negative nasopharyngeal swabs had other specimens tested positive. There was no significant correlation between antibody level and days after symptoms onset or viral load. Conclusions Other specimens could be positive in patients with negative nasopharyngeal swabs, suggesting that for patients in the recovery period, specimens other than nasopharyngeal swabs should also be tested to avoid false negative results, and anal swabs are recommended. The antibody level had no correlation with days after symptoms onset or the viral load of nasopharyngeal swabs, suggesting that the antibody level may also be affected by other factors.
China has entered a new phase in blood safety and availability through persistent efforts in the past decades. Based on national data from 2008 to 2012, we present a comprehensive review on the blood services ranging from policy and organization, supply, donors, screening and processing, and clinical use to government response in contemporary China. Current evidence suggests that the Chinese blood industries, after continual efforts in reforms on the legal framework and national management system, have been in a relatively steady but bottleneck stage. Although the blood industries have had an impressive track record on management and resolving problems, such as low availability, limited donors, deficient laboratory tests, shortage of blood products, and unnecessary clinical usage of blood still exist nationwide. While medical technology and services have seen a rapid increase in progress in recent years, they have not coordinated with the development of the national health care system. This article presents an analysis with detailed data, rich contents, and recent response from the Chinese government, allowing readers to appreciate how China, a country with more than 19.13% of the world's population, has long endeavored to improve safety and availability of blood. Meantime, the article sincerely welcomes the guidance on policymaking and technical assistance from the international community. Data in this article do not include those of Hong Kong, Macao, or Taiwan.
Liver cirrhosis and hepatocellular carcinomas are major health problems of chronic hepatitis B virus (HBV) infection. To date, rare model has reproduced liver fibrosis associated with long-term HBV infection which in turn has hindered both the understanding of HBV biology and the development of new treatment options. Here, using adeno-associated virus serotype 8 (AAV8) mediated delivery of a 1.2-kb HBV genome, we successfully generated a chronic HBV infectious mouse model that presents the associated liver fibrosis observed following human infection. After AAV8/HBV1.2 vector administration, mice demonstrated effective HBV replication and transcription which resulted in HBV antigen expression and viremia over 6 months. Although no obvious acute inflammatory response was noted, these mice still developed chronic liver disease and hepatic fibrogenesis as demonstrated by increased ground glass-like hepatocytes, an increasing trend of collagen deposition and upregulated fibrosis markers, including type I collagen, type III collagen, tissue inhibitor of metalloproteinase (TIMP), and transforming growth factor-β1(TGF-β1). Taken together, AAV-mediated HBV gene delivery to the mouse liver, induced HBV persistent infection accompanied by liver fibrosis which can serve as a model for investigating the precise mechanisms underlying liver fibrosis following chronic HBV infection as well as for the potential development of novel therapeutics.
Despite a steady increase in total blood collections and voluntary non-remunerated blood donors, China continues to have many challenges with its blood donation system. The country's donation rate remains low at 9‰, with over 60% of donors being first-time donors. Generally there is a lack of adequate public awareness about blood donation. The conservative donor selection criteria, the relatively long donation interval, and the small donation volume have further limited blood supply. To ensure a sufficient and safe blood supply that meets the increasing clinical need for blood products, there is an urgent need to strengthen the country's blood donor management. This comprehensive effort should include educating and motivating more individuals especially from the rural areas to be involved in blood donation, developing rational and evidence-based selection criteria for donor eligibility, designing a donor follow-up mechanism to encourage more future donations, assessing the current donor testing strategy, improving donor service and care, building regional and national shared donor deferral database, and enhancing the transparency of the blood donation system to gain more trust from the general public. The purpose of the review is to provide an overview of the key process of and challenges with the blood donor management system in China.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.