Abstract-A novel fabrication process, which uses wafer transfer and micro-electroplating technique, has been proposed and tested. In this paper, the effects of the diaphragm thickness and stress, the air-gap thickness, and the area ratio of acoustic holes to backplate on the sensitivity of the condenser microphone have been demonstrated since the performance of the microphone depends on these parameters. The microphone diaphragm has been designed with a diameter and thickness of 1.9 mm and 0.6 μ m, respectively, an air-g a p t h i c k n e s s o f 1 0 μ m, a n d a 2 4 % a r e a r a t i o of acoustic holes to backplate. To obtain a lower initial stress, the material used for the diaphragm is polyimide. The measured sensitivities of the microphone at the bias voltages of 24 V and 12 V are -45.3 and -50.2 dB/Pa (at 1 kHz), respectively. The fabricated microphone shows a flat frequency response extending to 20 kHz.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.