ObjectivesOur objectives were to review the literature to identify frailty instruments in use for transcatheter aortic valve implantation (TAVI) recipients and synthesise prognostic data from these studies, in order to inform clinical management of frail patients undergoing TAVI.MethodsWe systematically reviewed the literature published in 2006 or later. We included studies of patients with aortic stenosis, diagnosed as frail, who underwent a TAVI procedure that reported mortality or clinical outcomes. We categorised the frailty instruments and reported on the prevalence of frailty in each study. We summarised the frequency of clinical outcomes and pooled outcomes from multiple studies. We explored heterogeneity and performed subgroup analysis, where possible. We also used Grading of Recommendations, Assessment, Development and Evaluation (GRADE) to assess the overall certainty of the estimates.ResultsOf 49 included studies, 21 used single-dimension measures to assess frailty, 3 used administrative data-based measures, and 25 used multidimensional measures. Prevalence of frailty ranged from 5.67% to 90.07%. Albumin was the most commonly used single-dimension frailty measure and the Fried or modified Fried phenotype were the most commonly used multidimensional measures. Meta-analyses of studies that used either the Fried or modified Fried phenotype showed a 30-day mortality of 7.86% (95% CI 5.20% to 11.70%) and a 1-year mortality of 26.91% (95% CI 21.50% to 33.11%). The GRADE system suggests very low certainty of the respective estimates.ConclusionsFrailty instruments varied across studies, leading to a wide range of frailty prevalence estimates for TAVI recipients and substantial heterogeneity. The results provide clinicians, patients and healthcare administrators, with potentially useful information on the prognosis of frail patients undergoing TAVI. This review highlights the need for standardisation of frailty measurement to promote consistency.PROSPERO registration numberCRD42018090597.
Emerging evidence demonstrates that frailty measures can predict adverse outcomes after cardiac procedures. Our objectives were to examine whether the inclusion of frailty measures adds incremental predictive value to existing surgical risk prediction models in patients undergoing cardiac surgery and to evaluate the reporting and methods of studies that investigated the prediction of frailty measures in cardiology. The inclusion of frailty measures adds incremental predictive value on existing perioperative risk-scoring systems. We systematically searched the EMBASE, MEDLINE, and Web of Science databases for relevant studies. Studies were included according to predefined inclusion criteria. The quality of included studies was appraised using the QUADAS-2 tool. Data were extracted and synthesized according to predefined methods. Twelve studies were included in the analysis. Included studies demonstrated the incremental predictive value of frailty measures on existing surgical risk models for mortality, but the predictive value of frailty measures alone was not consistent across literature. Few studies that investigated the predictive ability of frailty measures reported all important model performance measures. When comparing the predictive value of frailty measures with existing models, few studies reported if the frailty measurement was separately performed from the existing perioperative risk assessment. The addition of frailty measures to the existing perioperative risk models improved the prediction performance for mortality, but the incorporation of frailty assessment into perioperative risk assessment requires further evidence before making health policy recommendations.
IntroductionAortic stenosis is a significant cause of morbidity and mortality in older patients. The advent of transcatheter aortic valve implantation (TAVI) offers an alternative to surgical aortic valve replacement for patients with severe symptomatic aortic stenosis who are at high or intermediate risk of adverse events. Existing evidence highlights the importance of frailty as a predictor of poor outcomes post-TAVI. The objective of this study is to review the operationalisation of frailty instruments for TAVI recipients and determine clinical outcomes and the change in quality of life in frail patients undergoing TAVI.Methods and analysisMethods are reported according to the Preferred Reporting Items for Systematic Review and Meta-Analysis Protocols 2015 checklist. We will search relevant databases to identify published, completed but unpublished and ongoing studies. We will include studies of patients with aortic stenosis, diagnosed as frail and who underwent a TAVI procedure that report mortality, clinical outcomes or health-related quality of life. Retrospective or prospective cohort studies, randomised controlled trials and non-randomised controlled trials will be eligible for inclusion. Two researchers will independently screen articles for inclusion, with disagreements resolved by a third reviewer. One researcher will extract data with audit by a second researcher. The risk of bias in studies will be evaluated using the Quality in Prognosis Studies tool. Meta-analysis of mortality, survival curve and the change in quality of life will be performed if appropriate. Subgroup analysis, sensitivity analysis and meta-regression will be performed if necessary.Ethics and disseminationDue to the nature of this study, no ethical issues are foreseen. We will disseminate the results of our systematic review through a peer-reviewed journal.Trial registration numberCRD42018090597.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.