Objective. The aim of the study was to analyze the efficacy of double-low dynamic contrast-enhanced CT (DCE-CT) and hepatic extracellular volume fraction (fECV) in the diagnosis of liver fibrosis (LF). Methods. A total of 200 patients with LF and cirrhosis who underwent the histopathological examination of liver biopsy and multiphase DCE-CT of the liver at the same time in our hospital (January 2020–December 2020) were selected as the research subjects, and the degree of liver fibrosis was staged according to pathological criteria to analyze the clinical diagnostic value of double-low DCE-CT and fECV. Results. Compared with the S2–S4 group, the S1 group had obviously higher Eaorta and HCT values ( P < 0.05 ), a lower fECV value ( P < 0.001 ), and lower serum IVC and LN levels (P < 0.001). Serum IVC and LN levels were positively correlated with fECV (r1 = 0.803 and r2 = 0.890; P < 0.001 ). The fECV had the highest specificity and negative predictive value in the diagnosis of S1 and had the highest sensitivity and positive predictive value in the diagnosis of S2–S4. Conclusion. The double-low DCE-CT and fECV can provide a reliable basis for the clinical diagnosis of LF, and their results will provide a new direction for the treatment of LF and have a high application value in the clinical practice.
The value of 320-slice spiral computed tomography (CT) perfusion imaging in staging and long-term dynamic evaluation of breast cancer was explored. 120 breast cancer patients who underwent preoperative CT examination and were confirmed by surgery and pathology were selected. All patients underwent preoperative TNM staging of breast cancer, with 120 cases in each stage. According to the results of 320-slice spiral CT, the postoperative pathology and surgical methods were compared and analyzed. CT diagnosis of breast cancer showed that T1 sensitivity was 71% and accuracy was 61%, T2 sensitivity was 74% and accuracy was 64%, T3 sensitivity was 94% and the accuracy was 84%, and the T4 sensitivity was 100% and the accuracy was 91%. The sensitivity of N1 stage was 71%, and the accuracy was 61%; and the sensitivity of N2 ~ N3 stage was 81%, and the accuracy was 76%. There were 7 cases of M1 with distant metastasis, the sensitivity was 71%, and the accuracy was 71%. At T1 stage, blood flow (BF) was 39.2 ± 16.7 mL/min/100 g, blood volume (BV) was 2.66 ± 1.4 mL/100 g, mean transit time (MTT) was 8.16 ± 2.7 s, and permeability surface (PS) was 16.6 ± 9.7 mL/min/100 g. 320-slice spiral CT perfusion imaging technology provided a new diagnostic mode for everyone, which can quantitatively identify breast cancer with multiple parameters, which was of great significance for clinical auxiliary diagnosis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.