Objective:The present study aimed to extract apparent diffusion coefficient (ADC) values from the diffusion-weighted imaging (DWI) sequence of endometrial lesions and compare them with tissue specimen results in order to determine the precision of ADC values in grading of malignant endometrial lesions.Methods:The present prospective study was conducted on 22 patients complaining of abnormal vaginal bleeding or evidence for endometrial thickening or masses detected using the ultrasound. Sampling was performed for pathological examination. MRI T2W+DWI+T1W+Post Contrast T1W were performed for patients. The statistical analysis was performed in SPSS 20 and MedCalc.Results:In this study, although the mean ADC value was lower in patients with endometrial cancer than those with benign endometrial lesions, the difference was not significant (0.86 ± 0.2 mm2/sec versus 1.33 ± 0.53 mm2/sec; P = 0.13). Using the cutoff point of 0.53, the sensitivity and specificity of ADC value for differentiating benign and malignant lesions, respectively, equaled 90.91 and 9.09, with an equal positive and negative predictive value of 50%. In patients with endometrioid adenocarcinoma, mean ADC value was 0.93 ± 0.15 in FIGO Grade I, and 0.76 ± 0.165 in FIGO Grade II. Based on the statistical test, no significant difference existed between the two groups in terms of ADC values.Conclusion:Results indicate that the use of a DWI sequence (ADC values) can prevent invasive measures in the diagnosis of benign endometrial lesions and the identification of malignant lesions with a high precision in many patients having accompanying diseases or other cases for which invasive measures cannot be used. Also, there is no significant difference in the mean ADC values between G1 and G2 of endometrioid carcinoma.
Introduction:
Ultrasound is highly effective, safe, and cost-effective for monitoring the hemodynamics and measuring the cardiac output of patients. This study aims to investigate the value of cardiac output by the measurement of common carotid artery flow, which is an inexpensive, simple, and accessible method.
Method:
Doppler ultrasound of the carotid artery at thyroid level was obtained from the patients admitted to Golestan and Imam Khomeyni Hospitals in Ahvaz (the result is recorded medially from the bilateral outputs unless otherwise prescribed on one side due to a problem such as a catheter or specific position). A transthoracic echocardiography was also recorded using a portable device to measure the left ventricular outlet of diameter 0.5 cm below the aortic valve in the left parasternal with a long axis view.
Results:
Of the 94 patients studied between the ages of 25 to 87 years, 53 (56.4%) were males and 41 (43.6%) females with a mean age of 53.61 with a standard deviation of 14.56. There was a direct and significant relationship between age and cardiac output using both echocardiography and color Doppler carotid ultrasound (
P
< 0.001).
Discussion:
The results of this study showed that the measurement of cardiac output using color Doppler ultrasound in the case of inaccessible emergency echocardiography is a cheap, simple, and accessible method for the hemodynamic evaluation of patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.