The major objective is to adopt, apply and test developed in-house algorithms for volumetric breast reconstructions from projection images, obtained in in-line phase-contrast mode. Four angular sets, each consisting of 17 projection images obtained from four physical phantoms, were acquired at beamline ID17, European Synchroton Radiation Facility, Grenoble, France. The tomosynthesis arc was ±32°. The physical phantoms differed in complexity of texture and introduced features of interest. Three of the used phantoms were in-house developed, and made of epoxy resin, polymethyl-methacrylate and paraffin wax, while the fourth phantom was the CIRS BR3D. The projection images had a pixel size of 47 µm × 47 µm. Tomosynthesis images were reconstructed with standard shift-and-add (SAA) and filtered backprojection (FBP) algorithms. It was found that the edge enhancement observed in planar x-ray images is preserved in tomosynthesis images from both phantoms with homogeneous and highly heterogeneous backgrounds. In case of BR3D, it was found that features not visible in the planar case were well outlined in the tomosynthesis slices. In addition, the edge enhancement index calculated for features of interest was found to be much higher in tomosynthesis images reconstructed with FBP than in planar images and tomosynthesis images reconstructed with SAA. The comparison between images reconstructed by the two reconstruction algorithms shows an advantage for the FBP method in terms of better edge enhancement. Phase-contrast breast tomosynthesis realized in in-line mode benefits the detection of suspicious areas in mammography images by adding the edge enhancement effect to the reconstructed slices.
Chlorophyll meters are portable devices used to assess and improve plants’ nitrogen management and to help farmers in the determination of the health condition of plants through leaf greenness measurements. These optical electronic instruments can provide an assessment of chlorophyll content by measuring the light passing through a leaf or by measuring the light radiation reflected from its surface. However, independently of the main principle of operation and use (e.g., absorbance vs. reflectance measurements), commercial chlorophyll meters usually cost hundreds or even thousands of euros, making them inaccessible to growers and ordinary citizens who are interested in self-cultivation, farmers, crop researchers, and communities lacking resources in general. A low-cost chlorophyll meter based on light-to-voltage measurements of the remaining light after two LED light emissions through a leaf is designed, constructed, evaluated, and compared against two well-known commercial chlorophyll meters, the SPAD-502 and the atLeaf CHL Plus. Initial tests of the proposed device on lemon tree leaves and on young Brussels sprouts plant leaves revealed promising results compared to the commercial instruments. The coefficient of determination, R2, was estimated to be 0.9767 for the SPAD-502 and 0.9898 for the atLeaf-meter in lemon tree leaves samples compared to the proposed device, while for the Brussels sprouts plant, R2 was estimated to be 0.9506 and 0.9624, respectively. Further tests conducted as a preliminary evaluation of the proposed device are also presented.
The aim of the study is to investigate the impact on image quality of using monochromatic beams for lower dose breast tomosynthesis (BT). For this purpose, modeling and simulation of BT and mammography imaging processes have been performed using two x-ray beams: one at 28kVp and a monochromatic at 19keV at different entrance surface air kerma ranging between 0.16 and 5.5 mGy. Two 4cm thick computational breast models in a compressed state were used: one simple homogeneous and one heterogeneous based on CT breast images, with compositions of 50% glandular-50% adipose and 40% glandular-60% adipose tissues by weight, respectively. Modeled lesions representing masses and calcifications were inserted within these breast phantoms. X-ray transport in the breast models was simulated with previously developed and validated Monte Carlo application. Results showed that for the same incident photon fluence, the use of the monochromatic beam in BT resulted in higher image quality compared to the one using polychromatic acquisition, especially in terms of contrast. For the homogenous phantom, the improvement ranged between 15% and 22% for calcifications and masses, respectively, while for the heterogeneous one this improvement was in the order of 33% for the masses and 17% for the calcifications. For different exposures, comparable image quality in terms of signal-difference-to-noise ratio and higher contrast for all features was obtained when using monochromatic 19keV beam at lower mean glandular dose compared to the polychromatic one. Monochromatic images provide also better detail and in combination with BT can lead to substantial improvement in visualization of features and particularly better edge detection of low-contrast masses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.