This study was aimed to assess patient dosimetry in interventional cardiology (IC) and radiology (IR) and radiation safety of the medical operating staff. For this purpose, four major Algerian hospitals were investigated. The data collected cover radiation protection tools assigned to the operating staff and measured radiation doses to some selected patient populations. The analysis revealed that lead aprons are systematically worn by the staff but not lead eye glasses, and only a single personal monitoring badge is assigned to the operating staff. Measured doses to patients exhibited large variations in the maximum skin dose (MSD) and in the dose area product (DAP). The mean MSD registered values are as follows: 0.20, 0.14 and 1.28 Gy in endoscopic retrograde cholangiopancreatography (ERCP), coronary angiography (CA) and percutaneous transluminal coronary angioplasty (PTCA) procedures, respectively. In PTCA, doses to 3 out of 22 patients (13.6 %) had even reached the threshold value of 2 Gy. The mean DAP recorded values are as follows: 21.6, 60.1 and 126 Gy cm(2) in ERCP, CA and PTCA procedures, respectively. Mean fluoroscopic times are 2.5, 5 and 15 min in ERCP, CA and PTCA procedures, respectively. The correlation between DAP and MSD is fair in CA (r = 0.62) and poor in PTCA (r = 0.28). Fluoroscopic time was moderately correlated with DAP in CA (r = 0.55) and PTCA (r = 0.61) procedures. Local diagnostic reference levels (DRLs) in CA and PTCA procedures have been proposed. In conclusion, this study stresses the need for a continuous patient dose monitoring in interventional procedures with a special emphasis in IC procedures. Common strategies must be undertaken to substantially reduce radiation doses to both patients and medical staff.
A pilot study has concerned the most frequent computed tomography examinations (CT). This represents the first results based on actual survey for diagnostic reference levels (DRLs) establishment in Algeria. A total number of 2540 patients underwent this survey that has included the recording of CT parameters, computed tomography dose index (CTDIvol) and dose-length product of the head, thorax, abdomen, abdomen–pelvis (AP), lumbar spine (LS) and thorax–abdomen–pelvis (TAP) performed on standard patients. The proposed DRLs are 71 mGy/1282 mGy.cm for head, 16 mGy/555 mGy.cm for thorax, 18 mGy/671 mGy.cm for abdomen, 21 mGy/950 mGy.cm for AP, 36 mGy/957 mGy.cm for LS and 18 mGy/994 mGy.cm for TAP. The rounded 75th percentile seems to be higher in some examinations compared to the literature. Our findings confirm the need to optimise our practice. These results provide a starting point for institutional evaluation of CT radiation doses.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.