5-S-cysteinyldopa is a well-known pigment intermediate and analysis of its plasma concentration is interesting for the early diagnosis, as well as for evaluation of treatment and follow-up of malignant melanoma. A determination method of 5-SCD in human plasma was developed using solid phase extraction (SPE) on disposable cartridges and liquid chromatography electrospray mass spectrometry (LC-ESI-MS-MS). Compound's sensitivity to light and oxidation requires the addition of anti-oxidative agents (AO), to work in acidic media at 4• C and to avoid light exposure of samples since blood collection. Different solid phases involving covalent binding to phenylboronic groups or dual retention mechanisms were evaluated and extraction cartridges containing both hydrophobic and strong cation exchange functionalities were finally selected. The LC separation of 5-SCD from endogenous catecholamines was achieved by gradient elution on a C18 stationary phase. 5-SCD was detected by multiple reaction monitoring (MRM) performed on ES(+) generated ions. Finally, the method was prevalidated in the lower ng/ml range. Good results with respect to accuracy, trueness and precision were obtained.
A method for the determination of three anabolic hormones (diethylstilbestrol, dienestrol and trenbolone) in calf urine is described. After enzymatic hydrolysis, the samples were cleaned up by C18 solid-phase extraction. Drugs were extracted with hexane and analyzed by isocratic elution on a Discovery RP-Amide C16 5 microns column with photodiode-array detection at 240 and 347 nm. Both retention time and UV spectra were used for identification. Detection limits for the HPLC system were calculated to be 0.3 ng injected for all analytes in the standard mixture. However, for urine samples these limits increased because of the presence of unidentified matrix components. After extraction from urine, the limits of detection for the whole analytical procedure were 5 and 10 ng injected for trenbolone and stilbenes, respectively. The average recoveries of the hormones from spiked samples were in the range 53.1-56.7% with RSD between 11.3 and 14.5% for the whole procedure in the concentration range 25-2.5 ng ml-1.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.