Campbell, B. C.V. et al. (2019) Penumbral imaging and functional outcome in patients with anterior circulation ischaemic stroke treated with endovascular thrombectomy versus medical therapy: a meta-analysis of individual patient-level data.ABSTRACT Background: CT-perfusion (CTP) and MRI may assist patient selection for endovascular thrombectomy. We aimed to establish whether imaging assessments of ischaemic core and penumbra volumes were associated with functional outcomes and treatment effect.
Campbell, B. C. V. et al. (2018) Effect of general anaesthesia on functional outcome in patients with anterior circulation ischaemic stroke having endovascular thrombectomy versus standard care: a meta-analysis of individual patient data. Lancet Neurology, 17(1), pp. 47-53. (doi:10.1016/S1474-4422(17)30407-6) This is the author's final accepted version.There may be differences between this version and the published version. You are advised to consult the publisher's version if you wish to cite from it.http://eprints.gla.ac.uk/149670/ variables. An alternative approach using propensity-score stratification was also used. To account for between-trial variance we used mixed-effects modeling with a random effect for trial incorporated in all models. Bias was assessed using the Cochrane tool.Findings: Of 1764 patients in 7 trials, 871 were allocated to endovascular thrombectomy. After exclusion of 74 patients (72 who did not undergo the procedure and 2 with missing data on anaesthetic strategy), 236/797 (30%) of endovascular patients were treated under GA. At baseline, GA patients were younger and had shorter time to randomisation but similar pre-treatment clinical severity compared to non-GA. Endovascular thrombectomy improved functional outcome at 3 months versus standard care in both GA (adjusted common odds ratio (cOR) 1·52, 95%CI 1·09-2·11, p=0·014) and non-GA (adjusted cOR 2·33, 95%CI 1·75-3·10, p<0·001) patients. However, outcomes were significantly better for those treated under non-GA versus GA (covariate-adjusted cOR 1·53, 95%CI 1·14-2·04, p=0·004; propensitystratified cOR 1·44 95%CI 1·08-1·92, p=0·012). The risk of bias and variability among studies was assessed to be low.Interpretation: Worse outcomes after endovascular thrombectomy were associated with GA, after adjustment for baseline prognostic variables. These data support avoidance of GA whenever possible. The procedure did, however, remain effective versus standard care in patients treated under GA, indicating that treatment should not be withheld in those who require anaesthesia for medical reasons.
Funding:The HERMES collaboration was funded by an unrestricted grant from Medtronic to the University of Calgary.
Research in contextEvidence before this study between abolition of the thrombectomy treatment effect in MR CLEAN and no effect in THRACE. Three single-centre randomised trials of general anaesthesia versus conscious sedation found either no difference in functional outcome between groups or a slight benefit of general anaesthesia.
Added value of this studyThese data from contemporary, high quality randomised trials form the largest study to date of the association between general anesthesia and the benefit of endovascular thrombectomy versus standard care. We used two different approaches to adjust for baseline imbalances (multivariable logistic regression and propensity-score stratification). We found that GA for endovascular thrombectomy, as practiced in contemporary clinical care across a wide range of expert centres during the rand...
Our results demonstrate the effectiveness of the technique, a small rate of procedural complications, and long-term tolerance of the Neuroform Stent. Despite some evidence of early aneurysmal recurrence, long-term durability of stent-assisted aneurysm occlusion is stable after the first year.
Background and purposeTo evaluate the safety and effectiveness of the low-profile braided intracranial stents called the Low Profile Visualized Intraluminal Support (LVIS) devices for stent-assisted coil embolization of wide-necked intracranial aneurysms.Materials and methodsThis was a prospective, multicenter, observational study of unruptured and ruptured intracranial aneurysms treated with the LVIS devices. Imaging and clinical data were independently analyzed respectively by CoreLab and Clinical Event Committee. Primary endpoints were clinical safety, effectiveness, and angiographic stability of the results at 6 and 18 months.ResultsTen centers participated in the study; 102 patients were included and 90 patients (42.2% men, 57.8% women) were eventually analyzed, among which 27 (30.0%) had multiple aneurysms. Twenty-three (25.6%) were ruptured aneurysms, four of which (4.4%) were treated in the acute phase. One aneurysm was treated per patient; 92 LVIS and LVIS Jr devices were placed overall. The total aneurysm occlusion rate was 91.0% on immediate post-procedure angiograms, which remained unchanged at 6-month follow-up and was 92.4% at 18-month follow-up. One patient (1.1%) underwent retreatment between 6 and 18 months of follow-up. A modified Rankin score of 0 was documented for most cases immediately after the procedure (86.7%) and at 6-month (86.8%) and 18-month (83.3%) follow-up. The overall permanent morbidity rate at 18 months was 5.6% and the overall rate of events with sequelae related to the stent was 2.2%. The 18-month procedure-related mortality rate was 3.3%. No patient was deemed to require retreatment at 18-month follow-up.ConclusionThe LVIS/LVIS Jr endovascular devices are safe and effective in the treatment of ruptured and unruptured intracranial aneurysms, with acceptable complication rates, very high immediate total occlusion rates, and stable angiographic results.
We report three cases of portal venous gas detected on sonography without any portal abnormality on CT. In such a situation portal gas could correspond to a tiny amount of intraluminal gas after blunt abdominal trauma or, in contrast, to large or very large quantities of high blood-solubility gases in case of septicemia. Outcome was favorable in all three cases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.