In fluid mechanics, the large pressure fluctuation caused by the rapid change of fluid flow in a closed pipeline is called water hammer. It has huge destructive power for pressurized water pipelines, which often lead to pipeline leakage or even burst. In this paper, through the analysis of the dynamic characteristics of the gas in the pressurized water pipeline, the necessity of setting the air valve is drawn. Then based on the Bentley HAMMER model, combined with the example of the reservoir water pipeline engineering, the water hammer analysis was carried out. Compared with the maximum pressure head before and after adding the air valve, it is reduced from 126.89 m to 62.11 m, a decrease of about 50%. At the same time, the negative pressure in the pipeline under transient conditions is also eliminated. The results show that the air valve used in the pressure water pipeline has a good effect on the prevention of water hammer.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.