BackgroundThis study examined the effect of treatment with a novel biomechanical device on the level of pain and function in patients with knee OA.MethodsPatients with bilateral knee OA were enrolled to active and control groups. Patients were evaluated at baseline, at 4 weeks and at the 8-week endpoint. A novel biomechanical device was individually calibrated to patients from the active group. Patients from the control group received an identical foot-worn platform without the biomechanical elements. Primary outcomes were the WOMAC Index and ALF assessments.ResultsThere were no baseline differences between the groups. At 8 weeks, the active group showed a mean improvement of 64.8% on the WOMAC pain scale, a mean improvement of 62.7% on the WOMAC function scale, and a mean improvement of 31.4% on the ALF scale. The control group demonstrated no improvement in the above parameters. Significant differences were found between the active and control groups in all the parameters of assessment.ConclusionsThe biomechanical device and treatment methodology is effective in significantly reducing pain and improving function in knee OA patients.The study is registered at clinicaltrials.gov, identifier NCT00457132, http://www.clinicaltrials.gov/ct/show/NCT00457132?order=1
Background:Standard gauze field dressings and direct pressure occasionally are inadequate for the control of hemorrhage. QuikClot® Combat Gauze™ (QCG) combines surgical gauze with an inorganic material and is approved by the Food and Drug Administration and by the Israeli Standards Institute for external hemorrhage control. The purpose of this article is to report clinical use of this dressing during Operation Cast Lead in the Gaza strip during January 2009.Methods:QuikClot Combat Gauze and the QCG guidelines were issued to advanced life support (ALS) providers during the preparations for the Operation.All cases of injuries involving hemorrhage were reviewed, as well as interviews with the ALS providers (physicians and paramedics) and injured soldiers.Results:Fourteen uses of QCG were reported and reviewed (out of a total of 56 hemostatic interventions in 35 cases). Dressings were applied to injuries to the head, neck, axilla, buttocks, abdomen, back, and pelvis in 10 cases, and to extremities in four cases. In 13 cases (93%), injuries were caused by blast or gunshot mechanisms. The success rate was reported as 79% (11/14). Failure to control hemorrhage was reported in three cases in three different locations: neck, buttock, and thigh. All failures were attributed to severe soft tissue and vascular injuries. No complications or adverse events were reported.Conclusions:This report on the clinical field use of the QCG dressing by ALS providers suggests that it is an effective and safe product, and applicable for prehospital treatment of combat casualties. This report further suggests that QCG should be issued to medics as well as ALS providers. Larger clinical investigations are needed to confirm these findings.
Several biomechanics treatments for knee osteoarthritis (OA) have emerged with the goal of reducing pain and improving function. Through this, researchers have hoped to achieve a transition from the pathological gait patterns to coordinated motor responses. The purpose of the study was to determine the long-term effects of a therapy using a biomechanical device in patients with knee OA. Patients with knee OA were enrolled to active and control groups. The biomechanical device used in therapy (AposTherapy) was individually calibrated to each patient in the active group. Patients in the control group received standard treatment. Outcomes were the Western Ontario and McMaster Osteoarthritis Index (WOMAC), Aggregated Locomotor Function (ALF), Short Form 36 (SF-36), and Knee Society Score assessments. The active and control groups were similar at the baseline (group difference in all scores P > 0.05). The active group showed a larger improvement over time between groups in all three WOMAC categories (F = 16.8, 21.7, and 18.1 for pain, stiffness, and function; all P < 0.001), SF-36 Physical Scale (F = 5.8; P = 0.02), Knee Society Knee Score (F = 4.3; P = 0.044
), and Knee Society Function Score (F = 6.5; P = 0.014
). At the two-year endpoint, the active group showed significantly better results (all P ≤ 0.001). The groups showed a difference of 4.9, 5.6, and 4.7 for the WOMAC pain, stiffness, and function scores, respectively, 10.8 s in ALF score, 30.5 in SF-36 Physical Scale, 16.9 in SF-36 Mental Scale, 17.8 in Knee Society Knee Score, and 25.2 in Knee Society Function Score. The biomechanical therapy examined was shown to significantly reduce pain and improve function and quality of life of patients with knee OA over the long term.
These findings imply that gun-shot entry wounds to the head are unevenly distributed. A partially bullet-proof protective helmet may prevent a substantial fraction of injuries (and fatalities) without a significant weight addition to the helmet.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.