New diphosphine ligands based on heterocyclic aromatics inducing very high regioselectivity in rhodium-catalyzed hydroformylation: effect of the bite angle Kranenburg, M.; van der Burgt, Y.E.M.; Kamer, P.C.J.; van Leeuwen, P.W.N.M.; Goubitz, K.; Fraanje, J. Published in: Organometallics DOI:10.1021/om00006a057Link to publication Citation for published version (APA):Kranenburg, M., van der Burgt, Y. E. M., Kamer, P. C. J., van Leeuwen, P. W. N. M., Goubitz, K., & Fraanje, J. (1995). New diphosphine ligands based on heterocyclic aromatics inducing very high regioselectivity in rhodiumcatalyzed hydroformylation: effect of the bite angle. Organometallics, 14, 3081-3089. DOI: 10.1021/om00006a057 General rightsIt is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), other than for strictly personal, individual use, unless the work is under an open content license (like Creative Commons). Disclaimer/Complaints regulationsIf you believe that digital publication of certain material infringes any of your rights or (privacy) interests, please let the Library know, stating your reasons. In case of a legitimate complaint, the Library will make the material inaccessible and/or remove it from the website. Please Ask the Library: http://uba.uva.nl/en/contact, or a letter to: Library of the University of Amsterdam, Secretariat, Singel 425, 1012 WP Amsterdam, The Netherlands. You will be contacted as soon as possible. The effect of the bite angle on regioselectivity in the rhodium-catalyzed hydroformylation reaction was studied with a series of bidentate diphosphines based on xanthene-like backbones as ligands. The bite angles of these ligands are fine-tuned by subtle alterations of the backbone of the ligands. When the bridge (X) in the 10-position of xanthene is varied, the bite angle as calculated from molecular mechanics increases stepwise from 102 to 131", whereas the changes in steric bulk and electronic effects are virtually absent for the following ligands: bis(2-(diphenylphosphino)phenyl) ether (DPEphos, 11, X = H, H; 4,6-bis(dipheny1phosphino)-10,lO-dimethylphenoxasilin (Sixantphos, 2), X = Si(CH&; 2,8-dimethyl-4,6-bis(dipheny1phosphino)phenoxathiin (Thixantphos, 3), X = S; 9,9-dimethyl-4,6-bis(dipheny1phosphino)xanthene (Xantphos, 4), X = C(CH&; 4,6-bis(diphenylphosphino)dibenzofuran (DBFphos, 51, X = bond. In the hydroformylation of l-octene the regioselectivity increased regularly with increasing bite angle: a t 40 "C up to 98.3% n-aldehyde was obtained with Xantphos, without isomerization or hydrogenation of l-octene. DBFphos does not form chelates, and consequently no increased selectivity was observed. The selectivity of the catalyst was almost unaffected by raising of the temperature to 80 "C, resulting in a higher turnover frequency (to0 with a constant selectivity: 97.7% n-aldehyde, 0.5% isomerization, and a tof value of 800 mol (mol of Rh)-l h-l. Xantphos induces the highest selectivity for the formation of the linear alde...
Analytical methods are pursued to measure the identity and location of biomolecules down to the subcellular ( m) level. Available mass spectrometric imaging methods either compromise localization accuracy or identification accuracy in their analysis of surface biomolecules. In this study, imaging FTICR-MS is applied for the spatially resolved mass analysis of rat brain tissue with the aim to optimize protein identification by the high mass accuracy and online MS/MS capabilities of the technique. Mass accuracies up to 6 ppm were obtained in the direct MALDI-analysis of the tissue together with a spatial resolution of 200 m. The spatial distributions of biomolecules differing in mass by less than 0.1 Da could be resolved, and are shown to differ significantly. Online MS/MS analysis of selected ions was demonstrated. A comparison of the FTICR-MS imaging results with stigmatic TOF imaging on the same sample is presented. To reduce the extended measuring times involved, it is recommended to restrict the FTICR-MS analyses to areas of interest as can be preselected by other, faster imaging methods. (J Am Soc Mass Spectrom 2007, 18, 145-151)
Mass spectrometric rearrangement reactions have been reported for a large variety of compounds such as peptides, lipids, and carbohydrates. In the case of carbohydrates this phenomenon has been described as internal residue loss. Resulting fragment ions may be misinterpreted as fragments arising from conventional glycosidic bond cleavages, which may result in incorrect structural assignment. Therefore, awareness of the occurrence of glycan rearrangements is important for avoiding misinterpretation of tandem mass spectra. In this review mass spectrometric rearrangements of both derivatized and underivatized (native) oligosaccharide structures are discussed. Similar phenomena have been reported for glycopeptides, labeled glycan structures and other biomolecules containing a carbohydrate part. Rearrangements in oligosaccharides and glycoconjugates have been observed with different types of mass spectrometers. Most of the observed carbohydrate rearrangement reactions appear to be linked to the presence of a proton. Hence, tandem mass spectrometric analysis of alkali adducts or deprotonated ions often prevents rearrangement reactions, while they may happen with high efficacy with protonated glycoconjugates.
Glycosylation is a post-translational modification of key importance with heterogeneous structural characteristics. Previously, we have developed a robust, high-throughput MALDI-TOF-MS method for the comprehensive profiling of human plasma N-glycans. In this approach, sialic acid residues are derivatized with linkage-specificity, namely the ethylation of α2,6-linked sialic acid residues with parallel lactone formation of α2,3-linked sialic acids. In the current study, this procedure was used as a starting point for the automation of all steps on a liquid-handling robot system. This resulted in a time-efficient and fully standardized procedure with throughput times of 2.5 h for a first set of 96 samples and approximately 1 h extra for each additional sample plate. The mass analysis of the thus-obtained glycans was highly reproducible in terms of relative quantification, with improved interday repeatability as compared to that of manual processing.
The Consortium for Top-Down Proteomics (www.topdownproteomics.org) launched the present study to assess the current state of top-down mass spectrometry (TD MS) and middle-down mass spectrometry (MD MS) for characterizing monoclonal antibody (mAb) primary structures, including their modifications. To meet the needs of the rapidly growing therapeutic antibody market, it is important to develop analytical strategies to characterize the heterogeneity of a therapeutic product's primary structure accurately and reproducibly. The major objective of the present study is to determine whether current TD/MD MS technologies and protocols can add value to the more commonly employed bottom-up (BU) approaches with regard to confirming protein integrity, sequencing variable domains, avoiding artifacts, and revealing modifications and their locations. We also aim to gather information
The emergence of complex protein therapeutics in general and monoclonal antibodies (mAbs) in particular have stimulated analytical chemists to develop new methods and strategies for their structural characterization. Mass spectrometry plays a key role in providing information on the primary amino acid sequence, post-translational modifications, and other structure characteristics that must be monitored during the manufacturing process and subsequent quality control assessment. In this study, we present a novel method that allows structural characterization of mAbs based on MALDI in-source decay (ISD) fragmentation, coupled with Fourier transform ion cyclotron resonance (FT-ICR) MS. The method benefits from higher resolution of absorption mode FT mass spectra, compared to magnitude mode, which enables simultaneous identification of ISD fragments from both the heavy and light chains with a higher confidence in a wide mass range up to m/z 13 500. This method was applied to two standard mAbs, namely NIST mAb and trastuzumab, in preparation for method application in an interlaboratory study on mAbs structural analysis coordinated by the Consortium for Top-Down Proteomics. Extensive sequence coverage was obtained from the middle-down analysis (IdeS- and GingisKHAN-digested mAbs) that complemented the top-down analysis of intact mAbs. In addition, MALDI FT-ICR MS of IdeS-digested mAbs allowed isotopic-level profiling of proteoforms with regard to heavy chain N-glycosylation.
An accurate mass measurement of a known protein provides information on potential amino acid deletions and post-translational modifications. Although this field is dominated by strategies based on electrospray ionization, mass spectrometry (MS) methods using matrix-assisted laser desorption/ionization (MALDI) have the advantage of yielding predominantly singly charged precursor ions, thus avoiding peak overlap from different charge states of multiple species. Such MALDI-MS methods require mass measurement at ultrahigh resolution, which is provided by Fourier transform ion cyclotron resonance (FTICR) mass analyzers. Recently, using a MALDI-FTICR-MS platform equipped with a 15 T magnet, we reported on the mass analysis of intact human serum peptides and small proteins with isotopic resolution up to ∼15 kDa and identified new proteoforms from an accurate measurement of mass distances. In the current study, we have used this FTICR system after an upgrade with a novel dynamically harmonized ICR cell, i.e., ParaCell, for mapping isotopically resolved intact proteins up to about 17 kDa and performed top-down MALDI in-source decay (ISD) analysis. Standard proteins myoglobin (m/z-value 16,950) and ribonuclease B (m/z-value 14,900) were measured with resolving powers of 62,000 and 61,000, respectively. Furthermore, it will be shown that (singly charged) MALDI-ISD fragment ions can be measured at isotopic resolution up to m/z-value 12,000 (e.g., resolving power 39,000 at m/z-value 12,000) providing more reliable identifications. Moreover, examples are presented of pseudo-MS(3) experiments on ISD fragment ions from RNase B by collisional-induced dissociation (CID).
High-throughput mass spectrometry (MS) glycomics is an emerging field driven by technological advancements including sample preparation and data processing. Previously, we reported an automated protocol for the analysis of N-glycans released from plasma proteins that included sialic acid derivatization with linkage-specificity, namely, ethylation of α2,6-linked sialic acid residues and lactone formation of α2,3-linked sialic acids. In the current study, each step in this protocol was further optimized. Method improvements included minimizing the extent of side-reaction during derivatization, an adjusted glycan purification strategy and mass analysis of the released N-glycans by ultrahigh resolution matrix-assisted laser desorption/ionization Fourier transform ion cyclotron resonance MS. The latter resolved peak overlap and simplified spectral alignment due to high mass measurement precision. Moreover, this resulted in more confident glycan assignments and improved signal-to-noise for low-abundant species. The performance of the protocol renders high-throughput applications feasible in the exciting field of clinical glycomics.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.