Abstract:The estimation of heart rate (HR) based on wearable devices is of interest in fitness. Photoplethysmography (PPG) is a promising approach to estimate HR due to low cost; however, it is easily corrupted by motion artifacts (MA). In this work, a robust approach based on random forest is proposed for accurately estimating HR from the photoplethysmography signal contaminated by intense motion artifacts, consisting of two stages. Stage 1 proposes a hybrid method to effectively remove MA with a low computation complexity, where two MA removal algorithms are combined by an accurate binary decision algorithm whose aim is to decide whether or not to adopt the second MA removal algorithm. Stage 2 proposes a random forest-based spectral peak-tracking algorithm, whose aim is to locate the spectral peak corresponding to HR, formulating the problem of spectral peak tracking into a pattern classification problem. Experiments on the PPG datasets including 22 subjects used in the 2015 IEEE Signal Processing Cup showed that the proposed approach achieved the average absolute error of 1.65 beats per minute (BPM) on the 22 PPG datasets. Compared to state-of-the-art approaches, the proposed approach has better accuracy and robustness to intense motion artifacts, indicating its potential use in wearable sensors for health monitoring and fitness tracking.
Wearable telemonitoring of electrocardiogram (ECG) based on wireless body Area networks (WBAN) is a promising approach in next-generation patient-centric telecardiology solutions. In order to guarantee long-term effective operation of monitoring systems, the power consumption of the sensors must be strictly limited. Compressed sensing (CS) is an effective method to alleviate this problem. However, ECG signals in WBAN are usually non-sparse, and most traditional compressed sensing recovery algorithms have difficulty recovering non-sparse signals. In this paper, we proposed a fast and robust non-sparse signal recovery algorithm for wearable ECG telemonitoring. In the proposed algorithm, the alternating direction method of multipliers (ADMM) is used to accelerate the speed of block sparse Bayesian learning (BSBL) framework. We used the famous MIT-BIH Arrhythmia Database, MIT-BIH Long-Term ECG Database and ECG datasets collected in our practical wearable ECG telemonitoring system to verify the performance of the proposed algorithm. The experimental results show that the proposed algorithm can directly recover ECG signals with a satisfactory accuracy in a time domain without a dictionary matrix. Due to acceleration by ADMM, the proposed algorithm has a fast speed, and also it is robust for different ECG datasets. These results suggest that the proposed algorithm is very promising for wearable ECG telemonitoring.
In the wearable health monitoring based on compressed sensing, atrial fibrillation detection directly from the compressed ECG can effectively reduce the time cost of data processing rather than classification after reconstruction. However, the existing methods for atrial fibrillation detection from compressed ECG did not fully benefit from the existing prior information, resulting in unsatisfactory classification performance, especially in some applications that require high compression ratio (CR). In this paper, we propose a deep learning method to detect atrial fibrillation directly from compressed ECG without reconstruction. Specifically, we design a deep network model for one-dimensional ECG signals, and the measurement matrix is used to initialize the first layer of the model so that the proposed model can obtain more prior information which benefits improving the classification performance of atrial fibrillation detection from compressed ECG. The experimental results on the MIT-BIH Atrial Fibrillation Database show that when the CR is 10%, the accuracy and F1 score of the proposed method reach 97.52% and 98.02%, respectively. Compared with the atrial fibrillation detection from original ECG, the corresponding accuracy and F1 score are only reduced by 0.88% and 0.69%. Even at a high CR of 90%, the accuracy and F1 score are still only reduced by 6.77% and 5.31%, respectively. All of the experimental results demonstrate that the proposed method is superior to other existing methods for atrial fibrillation detection from compressed ECG. Therefore, the proposed method is promising for atrial fibrillation detection in wearable health monitoring based on compressed sensing.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.