The gamma nail and proximal femoral locking plate (PFLP) are both used for fractures. A controlled study was performed to determine the optimal implant. To assess and analyze the clinical effects of gamma nails and PFLPs for patients with unstable intertrochanteric femoral fractures, specifically with broken lateral walls. Thirty-six patients with unstable intertrochanteric femoral fractures and broken lateral walls were treated with gamma nails or PFLPs and retrospectively studied. The clinical data were compared. Duration of surgery and early full weight-bearing time were significantly longer in the PFLP group compared to the gamma nail group (P < 0.05). However, intraoperative fluoroscopy frequency and total blood loss in the PFLP group were significantly less than those in the gamma nail group (P < 0.05). No significant differences were found in hospitalized days, Parker Palmer mobility scores, Harris hip scores, and complications between the two groups. No difference in hip-functional recovery was found between the gamma nail group and the PFLP group, indicating that both the gamma nail and PFLP were effective for unstable intertrochanteric femoral fractures with a broken lateral wall. However, early weight bearing on the fractures was not encouraged in patients treated with PFLP.
Background
Total hip arthroplasty (THA) for bony ankylosis is technically challenging in patients with ankylosing spondylitis (AS). This study aimed to determine the mid-term results of bilateral synchronous THA for bony ankylosis in patients with AS.
Methods
Nineteen cases of bony ankylosis in patients with AS who received bilateral synchronous THA were included in this study (17 males and 2 females, mean age 49.2 years). Disease duration was 5–38 years (mean 18 years and 6 months). All patients received cementless THA. Intraoperative blood loss, visual analog scale (VAS) score, and complications were assessed. Harris hip scores evaluated the clinical effect.
Results
Patients were followed up for 62–98 months (mean 82.5 months). VAS score decreased from 7.42 ± 0.92 to 2.42 ± 0.83, Harris hip score improved from 21.8 ± 7.2 to 80.3 ± 6.5, and the flexion-extension range of the hip improved from 0 to 142.3 ± 6.2°. One patient with septum bronchiale had a fracture intraoperatively and was treated with wire strapping. One patient had a traction injury of the femoral nerve postoperatively and recovered 1 year after the operation. Loosening and subsidence were not observed in all patients. Heterotopic bone formation was noted in 3 patients. No complications such as joint dislocation, acute infection, and deep vein thrombosis were found.
Conclusion
Bilateral synchronous THA was effective for bony ankylosis of the hip in patients with AS because it improved patients’ quality of life and had satisfactory mid-term outcomes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.