BACKGROUND:
Tools for the evaluation of gastric emptying have evolved over time. The purpose of this study was to show that the risk of pulmonary aspiration is not increased with carbohydrate drink, by demonstrating that the gastric antral cross-sectional area (CSA) of the NO-NPO group is either equivalent to or less than that of the NPO (nil per os) group.
METHODS:
Sixty-four patients scheduled for elective laparoscopic benign gynecologic surgery were enrolled and randomly assigned to the NPO group (n = 32) or the NO-NPO group (n = 32). After having a regular meal until midnight before surgery, the NPO group fasted until surgery, while the NO-NPO group ingested 400 mL of a carbohydrate drink at midnight and freely up to 2 hours before anesthesia. The primary outcome was the gastric antral CSA by gastric ultrasound in right lateral decubitus position (RLDP). Noninferiority was defined as a mean difference of CSA <2.8 cm2. Secondary outcomes included CSA in supine position, gastric volume (GV), GV per weight (GV/kg), GV/kg >1.5 mL/kg, and Perlas grade.
RESULTS:
CSA in RLDP was not different between the NPO group (6.25 ± 3.79 cm2) and the NO-NPO group (6.21 ± 2.48 cm2; P = .959). The mean difference of CSA in RLDP (NO-NPO group − NPO group) was 0.04 (95% confidence interval [CI], −1.56 to 1.64), which was within the noninferiority margin of 2.8 cm2. CSA was not different between the 2 groups (4.17 ± 2.34 cm2 in NPO group versus 4.28 ± 1.23 cm2 in NO-NPO group; P = .828). GV in NPO group (70 ± 56 mL) was not different from NO-NPO group (66 ± 36 mL; mean difference, 3.66; 95% CI, −20 to 27; P = .756). GV/kg in the NPO group (1.25 ± 1.00 mL/kg) was not different from the NO-NPO group (1.17 ± 0.67 mL/kg; P = .694). The incidence of GV/kg > 1.5 mL/kg was not different between NPO (31.3%) and NO-NPO group (21.9%; P = .768). The median (interquartile range) of the Perlas grade was 1 (0–1) in NPO group and 0.5 (0–1) in NO-NPO group (P = .871).
CONCLUSIONS:
Preoperative carbohydrates ingested up to 2 hours before anesthesia do not delay gastric emptying compared to midnight fasting, as evaluated with gastric ultrasound.
Objective This study was performed to compare two different shapes of stylets, 60° and J-shaped stylets, for intubation using the McGrath MAC® video laryngoscope (MVL). Methods Two hundred twenty-two patients undergoing surgery under general anesthesia were randomly allocated to Group J (n = 111) or Group 60° (n = 111) and intubated using the MVL with the stylet bent into the allocated shape. The time to intubation (TTI) and other intubating profiles were compared between the groups. Multivariate regression analysis was used to determine the relationship between factors related to difficult intubation and TTI. Results The TTI was not different between the two groups. There were also no differences in the intubating profiles between the two groups. In both groups, the TTI was longer with a modified Mallampati score (mMS) of ≥3 and percentage of glottic opening (POGO) score of <50. In Group J, the TTI was longer with a body mass index (BMI) of ≥30 kg/m2. Conclusion The TTI during tracheal intubation with the MVL was not different between the two groups. The TTI was longer with an mMS of ≥3 and POGO score of <50. In Group J, the TTI was longer with a BMI of ≥30 kg/m2.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.