It is well known that science can be misused to hinder the resolution (i.e., the elimination and/or control) of a health problem. To recognize distorted and misapplied epidemiological science, a 33-item “Toolkit for detecting misused epidemiological methods” (hereinafter, the Toolkit) was published in 2021. Applying the Toolkit, we critically evaluated a review paper entitled, “Lessons learned from Chernobyl and Fukushima on thyroid cancer screening and recommendations in the case of a future nuclear accident” in Environment International in 2021, published by the SHAMISEN (Nuclear Emergency Situations - Improvement of Medical and Health Surveillance) international expert consortium. The article highlighted the claim that overdiagnosis of childhood thyroid cancers greatly increased the number of cases detected in ultrasound thyroid screening following the 2011 Fukushima nuclear accident. However, the reasons cited in the SHAMISEN review paper for overdiagnosis in mass screening lacked important information about the high incidence of thyroid cancers after the accident. The SHAMISEN review paper ignored published studies of screening results in unexposed areas, and included an invalid comparison of screenings among children with screenings among adults. The review omitted the actual state of screening in Fukushima after the nuclear accident, in which only nodules > 5 mm in diameter were examined. The growth rate of thyroid cancers was not slow, as emphasized in the SHAMISEN review paper; evidence shows that cancers detected in second-round screening grew to more than 5 mm in diameter over a 2-year period. The SHAMISEN consortium used an unfounded overdiagnosis hypothesis and misguided evidence to refute that the excess incidence of thyroid cancer was attributable to the nuclear accident, despite the findings of ongoing ultrasound screening for thyroid cancer in Fukushima and around Chernobyl. By our evaluation, the SHAMISEN review paper includes 20 of the 33 items in the Toolkit that demonstrate the misuse of epidemiology. The International Agency for Research on Cancer meeting in 2017 and its publication cited in the SHAMISEN review paper includes 12 of the 33 items in the Toolkit. Finally, we recommend a few enhancements to the Toolkit to increase its utility.
In semiconductor manufacturing, accurate measurement of shapes and sizes of fabricated features is required. These measurements are carried out using critical dimension scanning electron microscope (CD-SEM). Positions of edges are often unclear because of charging. Depending on the SEM setup and the pattern under measurement, the effect of charging varies. The influence of measurement conditions can be simulated and optimized. A Monte Carlo electron beam simulation tool was developed, which takes into account electron scattering and charging. CD-SEM imaging of silicon dioxide lines on silicon was studied. In the experiment, changes in the beam voltage were found to result in contrast tone reversal. The same effect was also found in simulations considering charging. The time dependence of contrast variation was studied. A good agreement between simulation and measurement was found. The simulation software proved reliable in predicting SEM images, which makes it an important instrument to optimize settings of electron beam systems.
A multiscale simulation model is developed for optimizing the parameters of SiO 2 plasma-enhanced atomic layer deposition of high-aspect-ratio hole patterns in three-dimensional (3D) stacked memory. This model takes into account the diffusion of a precursor in a reactor, that in holes, and the adsorption onto the wafer. It is found that the change in the aperture ratio of the holes on the wafer affects the concentration of the precursor near the top of the wafer surface, hence the deposition profile in the hole. The simulation results reproduced well the experimental results of the deposition thickness for the various hole aperture ratios. By this multiscale simulation, we can predict the deposition profile in a high-aspect-ratio hole pattern in 3D stacked memory. The atomic layer deposition parameters for conformal deposition such as precursor feeding time and partial pressure of precursor for wafers with various hole aperture ratios can be estimated.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.