BACKGROUNDCoronary revascularization guided by fractional flow reserve (FFR) is associated with better patient outcomes after the procedure than revascularization guided by angiography alone. It is unknown whether the instantaneous wave-free ratio (iFR), an alternative measure that does not require the administration of adenosine, will offer benefits similar to those of FFR. METHODSWe randomly assigned 2492 patients with coronary artery disease, in a 1:1 ratio, to undergo either iFR-guided or FFR-guided coronary revascularization. The primary end point was the 1-year risk of major adverse cardiac events, which were a composite of death from any cause, nonfatal myocardial infarction, or unplanned revascularization. The trial was designed to show the noninferiority of iFR to FFR, with a margin of 3.4 percentage points for the difference in risk. RESULTSAt 1 year, the primary end point had occurred in 78 of 1148 patients (6.8%) in the iFR group and in 83 of 1182 patients (7.0%) in the FFR group (difference in risk, −0.2 percentage points; 95% confidence interval [CI], −2.3 to 1.8; P<0.001 for noninferiority; hazard ratio, 0.95; 95% CI, 0.68 to 1.33; P = 0.78). The risk of each component of the primary end point and of death from cardiovascular or noncardiovascular causes did not differ significantly between the groups. The number of patients who had adverse procedural symptoms and clinical signs was significantly lower in the iFR group than in the FFR group (39 patients [3.1%] vs. 385 patients [30.8%], P<0.001), and the median procedural time was significantly shorter (40.5 minutes vs. 45.0 minutes, P = 0.001). CONCLUSIONSCoronary revascularization guided by iFR was noninferior to revascularization guided by FFR with respect to the risk of major adverse cardiac events at 1 year. The rate of adverse procedural signs and symptoms was lower and the procedural time was shorter with iFR than with FFR. ( Use of Instantaneous Wave-free R atio in PCI F or the past 20 years, physiological measurements obtained during invasive procedures have been used to guide coronary revascularization. Pioneering work supported the use of flow measurements to make safe decisions about revascularization, 1,2 but this approach was soon superseded by the use of fractional flow reserve (FFR), which measures pressure as a surrogate of flow to estimate the severity of stenosis. 3-5 FFR was successful largely because of its technical simplicity and because clinical trials showed that it was associated with improved clinical outcomes after percutaneous coronary intervention (PCI). 6,7 Consequently, FFR is now included in the appropriate-use criteria for coronary angiography and in the American College of Cardiology-American Heart Association-European Society of Cardiology guidelines; despite these recommendations, its adoption remains limited. [8][9][10] FFR must be measured during maximal hyperemia, which is typically induced with the administration of a potent intravenous or intracoronary vasodilator, such as adenosine. 11 Several studies have...
The diagnostic accuracy of FFR-CT varies markedly across the spectrum of disease. This analysis allows clinicians to interpret the diagnostic accuracy of individual FFR-CT results. In combination with patient-specific factors, clinicians can use FFR-CT to judge when the cost and risk of an invasive angiogram may safely be avoided.
ObjectivesThe study sought to determine the coronary flow characteristics of angiographically intermediate stenoses classified as discordant by fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR).BackgroundDiscordance between FFR and iFR occurs in up to 20% of cases. No comparisons have been reported between the coronary flow characteristics of FFR/iFR discordant and angiographically unobstructed vessels.MethodsBaseline and hyperemic coronary flow velocity and coronary flow reserve (CFR) were compared across 5 vessel groups: FFR+/iFR+ (108 vessels, n = 91), FFR–/iFR+ (28 vessels, n = 24), FFR+/iFR– (22 vessels, n = 22), FFR–/iFR– (208 vessels, n = 154), and an unobstructed vessel group (201 vessels, n = 153), in a post hoc analysis of the largest combined pressure and Doppler flow velocity registry (IDEAL [Iberian-Dutch-English] collaborators study).ResultsFFR disagreed with iFR in 14% (50 of 366). Baseline flow velocity was similar across all 5 vessel groups, including the unobstructed vessel group (p = 0.34 for variance). In FFR+/iFR– discordants, hyperemic flow velocity and CFR were similar to both FFR–/iFR– and unobstructed groups; 37.6 (interquartile range [IQR]: 26.1 to 50.4) cm/s vs. 40.0 [IQR: 29.7 to 52.3] cm/s and 42.2 [IQR: 33.8 to 53.2] cm/s and CFR 2.36 [IQR: 1.93 to 2.81] vs. 2.41 [IQR: 1.84 to 2.94] and 2.50 [IQR: 2.11 to 3.17], respectively (p > 0.05 for all). In FFR–/iFR+ discordants, hyperemic flow velocity, and CFR were similar to the FFR+/iFR+ group; 28.2 (IQR: 20.5 to 39.7) cm/s versus 23.5 (IQR: 16.4 to 34.9) cm/s and CFR 1.44 (IQR: 1.29 to 1.85) versus 1.39 (IQR: 1.06 to 1.88), respectively (p > 0.05 for all).ConclusionsFFR/iFR disagreement was explained by differences in hyperemic coronary flow velocity. Furthermore, coronary stenoses classified as FFR+/iFR– demonstrated similar coronary flow characteristics to angiographically unobstructed vessels.
Overall, deferral of revascularization is equally safe with both iFR and FFR, with a low MACE rate of about 4%. Lesions were more frequently deferred when iFR was used to assess physiological significance. In deferred patients presenting with ACS, the event rate was significantly increased compared with SAP at 1 year.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers