We describe a new model to directly measure hydraulic conductivity in a rabbit glaucoma surgery implant model. The principal physiologic endpoint of glaucoma surgery can be reliably quantified and consistently measured with this model. At 28 days post glaucoma filtration surgery, a rabbit bleb capsule has significantly reduced tissue hydraulic conductivity, in line with loss of implant outflow facility, and increased thickness and density of fibrous encapsulation.
IMPORTANCE Control of intraocular pressure after implantation of a glaucoma drainage device (GDD) depends on the porosity of the capsule that forms around the plate of the GDD.OBJECTIVE To compare capsular porosity after insertion of 2 different GDDs using a novel implant and measurement system. DESIGN, SETTING, AND SUBJECTSWe performed an experimental interventional study at an eye research facility in a tertiary eye care center. Testing was performed on 22 adult New Zealand white rabbits that received the experimental GDD or an existing GDD.INTERVENTIONS A new experimental GDD, the Center for Eye Research Australia (CERA) implant, was created using computer-aided design and a 3-dimensional printer. The CERA GDDs were implanted in the eyes of rabbits randomized into 1 of the following 3 groups: with no connection to the anterior chamber (n = 7), with connection to the anterior chamber for 1 week (n = 5), and with connection to the anterior chamber for 4 weeks (n = 5). In a control group (n = 5), a pediatric GDD was implanted without connection to the anterior chamber. We measured the capsular porosity using a pressure-gated picoliter pump at a driving pressure of 12 mm Hg. The animals were killed humanely for histologic study. MAIN OUTCOMES AND MEASURESPorosity of the fibrous capsule around the implant. RESULTSWe found no difference in mean (SEM) capsular porosity between the CERA (3.39 [0.76; 95% CI, 1.43-5.48] μL/min) and pediatric (4.52 [0.52; 95% CI, 3.19-5.95] μL/min) GDDs (P = .28, unpaired t test) at 4 weeks without aqueous exposure. Mean (SEM) capsular porosity of CERA GDDs connected to the anterior chamber at 1 week was 2.46 (0.36; 95% CI, 1.55-3.44) μL/min but decreased to 0.67 (0.07; 95% CI, 0.49-0.86) μL/min at 4 weeks (P = .001, unpaired t test). CONCLUSIONS AND RELEVANCEOur experimental method permits direct measurement of capsular porosity of an in situ GDD. In a comparison between an experimental (CERA) and an existing GDD, no differences were identified in capsular porosity or histologic reaction between the implants. These results suggest that the CERA GDD model can be used to test key components of glaucoma surgery and implant design.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.