A passively Q-switched Tm,Ho:GdVO4 laser operating at cryogenic temperature with a Cr(2+):ZnS saturable absorber pumped with continuous wave LDs was demonstrated. The performance of the laser was investigated through changing the distance between Cr(2+):ZnS and output coupler. The maximum pulse energy of 70.5 μJ was obtained at 10 W input power. The maximum average output power of PQS laser was up to 3.2 W at the pump power of 22.8 W, corresponding to CW output power of 7.4 W, pulse repetition frequency of 52 kHz, and a pulse width of 389 ns. The M(2) factor measured by the traveling knife-edge method was ~1.1 in x and y directions with near-diffraction limited beam quality.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.