This paper describes a novel free-flow electrophoresis (FFE), which is joined with gratis gravity, gas cushion injector (GCI) and self-balance collector instead of multiple channel pump, for the purpose of preparative purification. The FFE was evaluated by systemic experiments. The results manifest that (i) even though one-channel peristaltic pump is used for the driving of background buffer, there is still stable flow in the FFE chamber; (ii) the stable flow is induced by the gravity-induced pressure due to the difference of buffer surfaces in the GCI and self-balance collector; (iii) the pulse flow of background buffer induced by the peristaltic pump is greatly reduced by the GCI with good compressibility of included air; (iv) the FFE can be well used for zone electrophoretic separation of amino acids; (v) up to 20 inlets simultaneous sample injection and up to five to tenfold condensation of amino acid can be achieved by combining the FFE device with the method of moving reaction boundary. To the best of authors' knowledge, FFE has not been used for such separation and condensation of amino acids. The relevant results achieved in the paper have evident significance for the development of preparative FFE.
A large-scale free-flow electrophoresis (LS-FFE) is often too large for cell separation of lab scale, whereas micro-FFE (μFFE) has great difficulty in cell isolation due to easy blockage by cell accumulation in μFFE. In this study, a mid-scale FFE (MS-FFE) is developed for cell and protein separations. The volume of the separation chamber (70×40×0.1-0.8 mm) is from 280 μL to 2.24 mL, much lower than that in an LS-FFE but higher than that in a μFFE. Gravity is used for uniform flow of the background buffer only via a single pump with 16 channels and the sample is injected via an adjuster originally used for clinical intravenous injection. The experiments reveal that the hydrodynamic and electrohydrodynamic flows are much stable, and the Joule heat can be effectively dispersed without obvious positive or negative deviation as shown by the omega plots. By the device, Escherichia coli and Staphylococcus aureus, which easily accumulate to block μFFE and are separated with difficulty due to their same negative charges carried, can be well isolated under the conditions of 4.5 mM pH 8.5 Tris-boric buffer (4.5 mM Tris, 4.5 mM boric acid) with 0.10 mM ethylene diamine tetraacetic acid and 5% m/v sucrose, 200 μL/min, 800 V, and sample injection via inlet 4. The mid-scale FFE device could also be used for the separation of three model proteins of horse heart cytochrome c, myoglobin and bovine serum albumin. The device has clear significance for mid-scale separation of cells and proteins.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.