This paper proposed a modified algorithm for controlling a single-phase split-source inverter. The proposed algorithm is a modified model predictive control based on Harris Hawks optimization, where the AC output voltage, the DC-link voltage, and the DC input current are controlled within one cost function. Hence, the discrete time models of both AC-side and DC-side are obtained. For proper operation of the modified MPC, each error term within the cost function has a weighting factor. Harris Hawks optimization technique is used to determine the weighting factors at each term of the cost function. The proposed algorithm is validated using MATLAB/Simulink. Simulation results show that the system has succeeded in controlling AC load voltage, input current, and achieving constant DC-link voltage over a wide operating range.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.