PC from 35 degrees C to 20 degrees C temporarily overrides fatigue mechanism(s) during intense intermittent resistance exercise. The mechanisms for this ergogenic function remain unknown.
We previously reported that cold application to the palms between sets of high-intensity bench press exercise produces an ergogenic effect in men. In this study, we hypothesized that palm cooling (PC) or heating during rest intervals between high-intensity weight training sets will increase total repetitions and exercise volume load (kilograms) in resistance trained female subjects in a thermoneutral (TN) environment. Eight female subjects (mean ± SD, age = 25 ± 6 years, height = 160 ± 6 cm, body mass = 56 ± 7 kg, 1-repetition maximum [1RM] = 52 ± 6 kg, weight training experience = 6 ± 2 years) completed 4 sets of 85% 1RM bench press exercise to failure, with 3-minute rest intervals. Exercise trials were performed in a counterbalanced order on 3 days, separated by at least 3 days in TN, Palm heating (PH), and PC conditions. Heating and cooling were applied by placing both hands in a hand cooling device with the hand plate set to 45° C for heating and 10° C for cooling. Data were analyzed using a 2-factor repeated-measures analysis of variance and Tukey's post hoc tests. Palm cooling repetitions were significantly higher than TN repetitions during the second set, and PH repetitions were significantly higher than those of TN during the fourth set. Total exercise volume load (kilograms) for both PC (1,387 ± 358) and PH (1,349 ± 267) were significantly higher than TN (1,187 ± 262). In women, both heating and cooling of the palms between sets of resistance exercise increased the total exercise volume load performed. This ergogenic response to a peripheral sensory input is consistent with the central governor theory of muscular fatigue.
This study examined whether palm cooling (PC) could reduce heat strain, measured through changes in core, mean skin, mean body temperatures, and thermal sensation in resting hyperthermic subjects wearing chemical protective garments. Ten male subjects performed three exercise bouts (6.1 km h(-1), 2-4% grade) in a hot, dry environment [mean (SD) air temperature 42.2 (0.5 degrees C), relative humidity 36.5 (1%)] until core temperature reached 38.8 degrees C. Subjects then simulated transport in an armoured vehicle by resting in a seated position for 50 min with either no cooling (NC), (PC at 10 degrees C) or palm cooling with vacuum application around the hand (PCVAC, 10 degrees C, 7.47 kPa negative pressure). Core, skin, and mean body temperatures with PC and PCVAC were lower (P < 0.05) than NC from 15 to 50 min of cooling, and thermal sensation was lower (P < 0.05) from 30 to 50 min, with no differences in any variables between PC and PCVAC. Maximal heat extraction averaged 42 (12 W), and core temperature was reduced by 0.38 (0.21 degrees C) after 50 min of PC. Heat extraction with PC was modest compared to other cooling approaches in the literature.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.