Purpose: This study compared the extended depth of focus (EDOF) intraocular lens (IOL) (ZXR00; Tecnis Symfony, Johnson & Johnson Vision, Santa Ana, CA, US) to a novel, higher-order aspheric monofocal IOL (ICB00; Tecnis Eyhance, Johnson & Johnson Vision, Santa Ana, CA, US) which uses the same platform and material. Methods: Medical records of patients undergoing cataract surgery with ZXR00 or ICB00 implantation between March 2020 and January 2021 and with the data available for the 3-month visit were reviewed. The uncorrected near, intermediate, and distance visual acuity (VA); corrected distance VA; and optical quality parameters were the main outcome measures. Results: Among the 174 enrolled patients, 72 and 102 received the ZXR00 and ICB00, respectively. The average patient ages were 59.6 ± 10.6 (range: 49 to 70) and 65.2 ± 8.2 (range: 45 to 82) years in the ZXR00 and ICB00 groups, respectively, with significantly older patients in the ICB00 group. The other baseline parameters were not different for the 2 groups. Compared to the ICB00 group, the ZXR00 group showed markedly superior near VA ( P < 0.05) at 3 months postoperatively. In terms of optical quality, ICB00 was, statistically, significantly superior to ZXR00. Conclusions: The ZXR00 showed remarkable near vision and defocus curve smoothness, while the ICB00 achieved better optical quality. The 2 IOLs had comparable distance and intermediate vision.
Purpose: To compare the lipid layer thickness (LLT), meibomian gland (MG) dropouts, and blinking pattern determined by the analysis of images acquired from the LipiView® II (LVII) and the IDRA® Ocular surface analyzer. Methods: A cross-sectional single-visit observational study was conducted. The LLT (minimum, maximum, and average), percentages of MG dropouts, and partial blink rates (PBR) were taken from both eyes of 47 participants using LVII and IDRA. Both devices were used to image the inferior eyelid of each participant in a random order. Results: Forty-seven participants (mean age 56.77 ± 14.47 (21–79) years, 66% female) completed the study. There was no significant difference in LLT between the two devices. A significant difference in percentages of MG dropouts was obtained between the LVII (36.51 ± 17.53) and the IDRA (45.36 ± 21.87), p = 0.003). There was also a significant difference in PBR between the LVII (0.51 ± 0.37) and the IDRA (0.23 ± 0.27), p < 0.001). Conclusion: No significant difference in LLT was obtained between LVII and IDRA. IDRA had a significantly lesser percentage of MG dropout and a higher PBR compared to LVII. These results indicate that these devices should not be used interchangeably for the evaluation of MG dropouts and PBR.
Purpose To elucidate the relationship between partial blink rate (PBR) and ocular surface parameters. Methods We conducted a retrospective cross-sectional study of the patients who visited the Kim's Eye Hospital between March 2020 and July 2020. Blinking dynamics, tear film lipid layer thickness (LLT), noninvasive tear film break-up time (NITBUT), tear meniscus height (TMH), and meibomian gland (MG) dropout rate were assessed using the IDRA Ò Ocular surface analyzer (SBM SISTEMI, Inc., Torino, Italy) (IDRA). Dry eye symptoms were quantified by the Standard Patient Evaluation of Eye Dryness (SPEED) questionnaire scores. Results A total of 47 non-Sjo ¨gren dry eye patients (47 right eyes, mean age = 56.8 ± 14.5 [20-75] years, 66% female) were enrolled. Among the ocular surface parameters, PBR had strong correlations with MG dropout rate (r = 0.811; p \ 0.01) and moderate correlations with SPEED scores (r = 0.596; p \ 0.01). MG dropout rate and age had moderate correlations with SPEED scores (r = 0.416; p = 0.04 and r = 0.322; p = 0.03, respectively). Comparisons by sex revealed no significant difference in characteristics, except for the TMH value. The TMH of female patients (0.17 ± 0.07) was significantly higher than that of males (0.14 ± 0.04; p = 0.04). LLT showed no significant correlation with the other variables. Conclusion PBR and MG dropout rates measured with IDRA were significantly correlated to dry eye symptoms.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.