This study proposes a field weakening control method with interpolation error compensation of the look-up table based permanent-magnet synchronous machine (PMSM) method. The look-up table (LUT) based control method has robust control characteristics compared to other control methods that use linear controllers for current reference generation. However, it is impossible to store all current references under all circumstances for torque commands. General LUT based control methods use two input parameters. In order to mitigate the effect of discretely stored data, two-dimensional interpolation is used to linearly interpolate values between discontinuous data. However, because the current trajectories of PMSMs are generally ellipsoidal, an error occurs between the linearly interpolated and controllable current references. This study proposes a method to compensate for this interpolation error using a feedforward controller for rapid compensation. The improvement using the proposed method is verified by experiment and simulation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.