Despite their many advantages and successes, molecular beacon (MB) hybridization probes have not been extensively used in microarray formats because of the complicating probe-substrate interactions that increase the background intensity. We have previously shown that tethering to surface-patterned microgels is an effective means for localizing MB probes to specific surface locations in a microarray format while simultaneously maintaining them in as water-like an environment as possible and minimizing probe-surface interactions. Here we extend this approach to include both real-time detection together with integrated NASBA amplification. We fabricate small (∼250 μm × 250 μm) simplex, duplex, and five-plex assays with microarray spots of controllable size (∼20 μm diameter), position, and shape to detect bacteria and fungi in a bloodstream-infection model. The targets, primers, and microgel-tethered probes can be combined in a single isothermal reaction chamber with no post-amplification labelling. We extract total RNA from clinical blood samples and differentiate between Gram-positive and Gram-negative bloodstream infection in a duplex assay to detect RNA- amplicons. The sensitivity based on our current protocols in a simplex assay to detect specific ribosomal RNA sequences within total RNA extracted from S. aureus and E. coli cultures corresponds to tens of bacteria per ml. We furthermore show that the platform can detect RNA- amplicons from synthetic target DNA with 1 fM sensitivity in sample volumes that contain about 12 000 DNA molecules. These experiments demonstrate an alternative approach that can enable rapid and real-time microarray-based molecular diagnostics.
Microgel tethering is a nontraditional method with which to bind oligonucleotide hybridization probes to a solid surface. Microgel-tethering physically positions the probes away from the underlying hard substrate and maintains them in a highly waterlike environment. This paper addresses the question of whether molecular crowding affects the performance of microgel-tethered molecular beacon probes. The density of probe-tethering sites is controlled experimentally using thin-film blends of biotin-terminated [PEG-B] and hydroxyl-terminated [PEG-OH] poly(ethylene glycol) from which microgels are synthesized and patterned by electron beam lithography. Fluorescence measurements indicate that the number of streptavidins, linear DNA probes, hairpin probes, and molecular beacon probes bound to the microgels increases linearly with increasing PEG-B/PEG-OH ratio. For a given tethering-site concentration, more linear probes can bind than structured probes. Crowding effects emerge during the hybridization of microgel-tethered molecular beacons but not during the hybridization of linear probes, as the tethering density increases. Crowding during hybridization is associated with conformational constraints imposed by the close proximity of closed and hybridized structured probes. The signal-to-background ratio (SBR) of hybridized beacons is highest and roughly constant for low tethering densities and decreases at the highest tethering densities. Despite differences between microgel tethering and traditional oligonucleotide surface-immobilization approaches, these results show that crowding defines an optimum tethering density for molecular beacon probes that is less than the maximum possible, which is consistent with previous studies involving various linear and structured oligonucleotide probes.
Solid-phase oligonucleotide amplification is of interest because of possible applications to next-generation sequencing, multiplexed microarray-based detection, and cell-free synthetic biology. Its efficiency is, however, less than that of traditional liquid-phase amplification involving unconstrained primers and enzymes, and understanding how to optimize the solid-phase amplification process remains challenging. Here, we demonstrate the concept of solid-phase nucleic acid sequence-based amplification (SP-NASBA) and use it to study the effect of tethering density on amplification efficiency. SP-NASBA involves two enzymes, avian myeloblastosis virus reverse transcriptase (AMV-RT) and RNase H, to convert tethered forward and reverse primers into tethered double-stranded DNA (ds-DNA) bridges from which RNA amplicons can be generated by a third enzyme, T7 RNA polymerase. We create microgels on silicon surfaces using electron-beam patterning of thin-film blends of hydroxyl-terminated and biotin-terminated poly(ethylene glycol) (PEG-OH, PEG-B). The tethering density is linearly related to the PEG-B concentration, and biotinylated primers and molecular beacon detection probes are tethered to streptavidin-activated microgels. While SP-NASBA is very efficient at low tethering densities, the efficiency decreases dramatically with increasing tethering density due to three effects: (a) a reduced hybridization efficiency of tethered molecular beacon detection probes; (b) a decrease in T7 RNA polymerase efficiency;
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.