The space charge effect has been clearly observed in the energy distributions of picosecond pulse beams from a spin-polarized electron microscope, and was found to depend upon the quantity of charge per pulse. The non-linear phenomena associated with this effect have also been replicated in beam simulations that take into account of a three-dimensional space charge. The results show that a charge of 500 aC/pulse provides the highest brightness with a 16-ps pulse duration, a 30-keV beam energy, and an emission spot of 1.8 μm. Furthermore, the degeneracy of the wave packet of the pulsed electron beam has been evaluated to be 1.6 × 10−5 with a charge of 100 aC/pulse, which is higher than that for a continuously emitted electron beam despite the low beam energy of 30 keV. The high degeneracy and high brightness contribute to the realization of high temporal and energy resolutions in low-voltage electron microscopy, which will serve to reduce radiolysis damage and enhance scattering contrast.
The brightness and interference fringes of a spin-polarized electron beam extracted from a semiconductor photocathode excited by laser irradiation are directly measured via its use in a transmission electron microscope. The brightness was 3.8 × 107 A cm−2 sr−1 for a 30-keV beam energy with the polarization of 82%, which corresponds to 3.1 × 108 A cm−2 sr−1 for a 200-keV beam energy. The resulting electron beam exhibited a long coherence length at the specimen position due to the high parallelism of (1.7 ± 0.3) × 10−5 rad, which generated interference fringes representative of a first-order correlation using an electron biprism. The beam also had a high degeneracy of electron wavepacket of 4 × 10−6. Due to the high polarization, the high degeneracy and the long coherence length, the spin-polarized electron beam can enhance the antibunching effect.
Pulse-mode operation was realized in spin-polarized transmission electron microscopy (SP-TEM) using a laser-driven electron gun with a GaAs-GaAsP strained-layer-superlattice photocathode. TEM images were acquired with a pulsed electron beam with a 5-μs pulse duration. Phase locking of wobbling TEM images was demonstrated using a pulsed beam with a 1-kHz repetition frequency, which matched the image wobbling frequency. It was found that in composite images formed by superimposing 2 × 10(4) separate single-pulse exposures, the amount of image blurring due to wobbling was a linear function of the pulse duration. These results suggest the possibility of pump-probe measurements in SP-TEM using the pulsed electron beam as a probe, allowing nanometer-scale time-resolved spin mapping.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.