The results indicate that smoking adversely effects spinal fusion. Particularly re-operations caused by pseudarthrosis occur at a higher rate in smokers than in non-smokers.
Total hip replacement in PWH leads to a significant increase of function, reduction of pain and a high satisfaction. Due to the relatively high complication rate (infections and aseptic loosening) compared to patients without haemophilia, an individual assessment of the risk-benefit ratio from surgical and haemostaseological point of view is needed.
Our study demonstrates excellent long-term survival of cementless femoral stem in combination with a threaded cup in young patients undergoing total hip arthroplasty.
The iFuse system is an effective and safe treatment for minimally invasive surgical arthrodesis of the SIJ. Pain and functional impairment can be significantly improved. However, in addition to this case series, further controlled studies are necessary, particularly in terms of a previous spinal fusion history.
Chronic low-back pain (CLBP) has an increasing incidence and yields a tremendous health economic burden. There are different anatomic structures that may be responsible for CLBP, such as lumbar intervertebral discs, sacroiliac joints, nerve root dura, fascia, ligaments, and muscles. However, to a large extent, CLBP is associated with structural changes in and around the facet (zygapophyseal) joint. If conservative treatment strategies fail, symptoms and pain can effectively be reduced by denervation or rhizotomy of the medial branch of the dorsal ramus of the spinal nerve through radiofrequency ablation. In this technical description with video, we present an endoscopic technique for radiofrequency rhizotomy. This technique has the advantage of directly visualizing the facet joint as well as its surrounding structures including the medial branches.
In the nonbleeding patient, constant low-level activation of coagulation enables a quick procoagulant response upon an injury. Conversely, local activation of coagulation might influence the systemic activity level of coagulation. To characterize this interaction in more detail, activity pattern analysis was performed in patients undergoing elective surgeries. Blood samples were taken before, during, and 24 hours after surgery from 35 patients undergoing elective minor (n = 18) and major (n = 17) orthopaedic surgeries. Plasma levels of thrombin and activated protein C (APC) were measured using oligonucleotide-based enzyme capture assays, while those of prothrombin fragment 1.2, thrombin–antithrombin-complexes, and D-dimer were measured using commercially available enzyme-linked immunosorbent assays. In vitro thrombin generation kinetics were recorded using calibrated automated thrombography. Results showed that median plasma levels of up to 20 pM thrombin and of up to 12 pM APC were reached during surgery. D-dimer levels started to increase at the end of surgery and remained increased 24 hours after surgery, while all other parameters returned to baseline. Peak levels showed no significant differences between minor and major surgeries and were not influenced by the activity state at baseline. In vitro thrombin generation kinetics remained unchanged during surgery. In summary, simultaneous monitoring of the procoagulant and anticoagulant pathways of coagulation demonstrates that surgical trauma is associated with increased systemic activities of both pathways. Activity pattern analysis might be helpful to identify patients at an increased risk for thrombosis due to an imbalance between surgery-related thrombin formation and the subsequent anticoagulant response.
Osteoarthritis is a common and progressive joint disorder. Despite its widespread, in clinical practice only late phases of osteoarthritis that are characterized by severe joint damage are routinely detected. Since osteoarthritis cannot be cured but relatively well managed, an early diagnosis and thereby early onset of disease management would lower the burden of osteoarthritis. Here we evaluated if biophysical parameters of small synovial fluid samples extracted by single molecule microscopy can be linked to joint damage. In healthy synovial fluid (ICRS-score < 1) hyaluronan showed a slower diffusion (2.2 μm2/s, N = 5) than in samples from patients with joint damage (ICRS-score > 2) (4.5 μm2/s, N = 16). More strikingly, the diffusion coefficient of hyaluronan in healthy synovial fluid was on average 30% slower than expected by sample viscosity. This effect was diminished or missing in samples from patients with joint damage. Since single molecule microscopy needs only microliters of synovial fluid to extract the viscosity and the specific diffusion coefficient of hyaluronan this method could be of use as diagnostic tool for osteoarthritis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.