Biodegradable polymer stent with shape memory effect is expected to be developed in the treatment of esophageal stenosis, most likely due to traditional stents having such shortages as considerable rigidity and nondegradation. A tubular stent with the inner and outer diameters of 28 and 30 mm was manufactured from biodegradable poly(ε-caprolactone-co-DL-lactide) (PCLA) copolymer consisting of ε-caprolactone and DL-lactide at a weight ratio of 10/90. A series of tests were accomplished to investigate its properties including shape memory effects (SMEs), compression property and influence of in vitro degradation of polymer matrix on its shape recovery and dilation force. Significantly, an implantation of the stent into a dog model was performed to evaluate its function for the treatment of esophageal stenosis. The deformed stent needs about 36 s to recover its initial shape in vitro in 37°C warm water. The primary animal experiment in vivo has revealed that the implanted deformed stent could be triggered by body temperature and expectedly returned to a nearly-round shape to support esophageal wall. Therefore, the biodegradable intelligent polymer stent may be great potential to displace the conventional metallic stents for the esophageal stenosis therapy.
Background: Iterative reconstruction algorithms are often used to reduce image noise in low-dose coronary computed tomography angiography (CCTA) but encounter limitations. The newly introduced deep learning image reconstruction (DLIR) algorithm may provide new opportunities. We assessed the image quality and diagnostic performance of DLIR in low radiation dose and contrast medium dose CCTA of pediatric patients with 70 kVp and a shortened injection protocol.Methods: This was a prospective study. A total of 27 consecutive arrhythmic pediatric patients were enrolled in the study group and underwent CCTA using a prospective ECG-triggered single-beat protocol: tube voltage 70 kVp, automatic tube current modulation for a noise index (NI) of 22, and contrast dose of 0.4-0.6 mL/kg. Images were reconstructed with DLIR. They were compared with 27 matched patients in the control group scanned with 80 kVp, a lower NI setting (NI =19), and a higher contrast dose (0.8-1.2 mL/kg).The images in the control group were reconstructed using the adaptive statistical iterative reconstruction (ASIR-V) algorithm. The image contrast, image quality, and diagnostic confidence were assessed by 2 experienced radiologists using a 5-point scale (1: nondiagnostic and 5: excellent). The CT value and standard deviation of the aorta and perivascular tissue were measured, and the contrast-to-noise ratio (CNR) for the aorta was calculated. The contrast medium and radiation doses were compared. Results: The study and control groups had similar image contrast scores (4.75±0.57 vs. 4.78±0.42), image quality scores (3.67±0.47 vs. 3.44±0.51), and diagnostic confidence (4.74±0.44 vs. 4.74±0.45) (all P>0.05). There was an adequate enhancement in the aorta (614.74±127.73 vs. 705.89±111.20 HU) and similar CNR (20.34±4.64 vs. 20.99±4.14) in both groups. The image noise of the study group was lower in the aorta (30.61±3.88 vs. 34.77±3.49) and similar in perivascular tissue (27.66±6.24 vs. 27.55±3.33) compared with the control group. The study group reduced the total contrast medium dose by 53% to 15.07±3.68 ml and radiation dose by 36% to 0.57±0.31 mSv. Conclusions:The DLIR algorithm in CCTA for children using 70 kVp tube voltage with a shortened contrast medium injection protocol maintains image quality and diagnostic confidence while significantly reducing contrast medium dose and radiation dose compared with the use of the conventional CCTA protocol.
The use of TDF in pregnant females with chronic HBV and LAM or LdT resistance was safe and effective.
Background and aims The formation of an intranuclear pool of covalently closed circular DNA (cccDNA) in the liver is the main cause of persistent hepatitis B virus (HBV) infection. Here, we established highly sensitive and specific methods to detect cccDNA based on CRISPR-Cas13a technology. Methods We used plasmid-safe ATP-dependent DNase (PSAD) enzymes and HindIII to digest loose circle rcDNA and double-stranded linear DNA, amplify specific HBV cccDNA fragments by rolling circle amplification (RCA) and PCR, and detect the target gene using CRISPR-Cas13a technology. The CRISPR-Cas13a-based assay for the detection of cccDNA was further clinically validated using HBV-related liver tissues, plasma, whole blood and peripheral blood mononuclear cells (PBMCs). Results Based on the sample pretreatment step, the amplification step and the detection step, we established a new CRISPR-Cas13a-based assay for the detection of cccDNA. After the amplification of RCA and PCR, 1 copy/μl HBV cccDNA could be detected by CRISPR/Cas13-assisted fluorescence readout. We used ddPCR, qPCR, RCA-qPCR, PCR-CRISPR and RCA-PCR-CRISPR methods to detect 20, 4, 18, 14 and 29 positive samples in liver tissue samples from 40 HBV-related patients, respectively. HBV cccDNA was almost completely undetected in the 20 blood samples of HBV patients (including plasma, whole blood and PBMCs) by the above 5 methods. Conclusions We developed a novel CRISPR-based assay for the highly sensitive and specific detection of HBV cccDNA, presenting a promising alternative for accurate detection of HBV infection, antiviral therapy evaluation and treatment guidance.
The TST STARR Plus is a simple, safe, and effective option for selected patients with ODS. Long-term prospective clinical studies are needed to validate the advantages of this emerging, novel procedure.
Background & Aims: The WHO declared to eliminate hepatitis B virus (HBV) by 2030. However, an increasing number of patients are presenting with low-level viremia (LLV) with the widespread use of antiviral medications. The diagnostic efficiency and coverage area of HBV infection are low. Hence, this study intended to drive the HBV infection detection to effectively adaptable for any small to medium-sized laboratory or field survey. Methods: We established, optimized, and evaluated a colloidal gold test strip for detection of HBV DNA based on CRISPR/Cas13a combined with recombinase-aided amplification (RAA) technology. Furthermore, 180 HBV-infected patients (including patients with different viral loads, LLV patients and dynamic plasma samples of patients on antiviral therapy) were enrolled for clinical validation. Results: The strip detection of HBV DNA was established based on RAA-CRISPR-Cas13a technology with a sensitivity of 10 1 copies/μL and a specificity of 100%. HBV DNA gradient concentration plasmids and clinical samples were effectively identified by this approach. The positive coincidence rate for LLV patients was 87%, while the negative coincidence rate was 100%. The positive coincidence rate reached 100% in LLV patients (viral loading >100 IU/mL). The sensitivity, specificity, positive predictive agreement (PPA) and negative predictive agreement (NPA) values of dynamic plasma detection in patients on antiviral therapy were 100%, 92.15%, 93.75%, and 100%, respectively. Conclusions: We develop rapid and portable RAA-CRISPR/Cas13a-based strip of HBV DNA detection for LLV patients. This study provides a visual and faster alternative to current PCR-based diagnosis for HBV infection.
Background The state-of-art motion correction algorithm is inadequate for correcting motion artifacts in coronary arteries in cardiovascular computed tomography angiography (CCTA) for children with high heart rates, and even less effective for heart structures beyond coronary arteries. Purpose This study aimed to evaluate the effectiveness of a second-generation, whole-heart motion correction algorithm in improving the heart image quality of CCTA for children with high heart rates. Materials and Methods Forty-two consecutive symptomatic cardiac patients with high heart rates (122.6 ± 18.8 beats/min) were enrolled. All patients underwent CCTA on a 256-row CT using a prospective electrocardiogram-triggered single-beat protocol. Images were reconstructed using a standard algorithm (STD), state-of-the-art first-generation coronary artery motion correction algorithm (MC1), and second-generation, whole-heart motion correction algorithm (MC2). The image quality of the origin of left coronary, right coronary, aortic valve, pulmonary valve, mitral valve, tricuspid valve, aorta root, pulmonary artery root, ventricular septum (VS), and atrial septum (AS) was assessed by 2 experienced radiologists using a 4-point scale (1, nondiagnostic; 2, detectable; 3, measurable; and 4, excellent); nonparametric test was used to analyze and compare the differences among 3 groups; and post hoc multiple comparisons were used between different methods. Results There were group differences for cardiac structures except VS and AS, with MC2 having the best image quality and STD having the worst image quality. Post hoc multiple comparisons showed that MC2 was better than MC1 and STD in all structures except VS and AS where all 3 algorithms performed equally, whereas MC1 was better than STD only in the origin of left coronary, right coronary, and mitral valve. Conclusions A second-generation, whole-heart motion correction algorithm further significantly improves cardiac image quality beyond the coronaries in CCTA for pediatric patients with high heart rates.
Double‐chambered left ventricle (DCLV) is a particularly rare congenital cardiovascular malformation that is difficult to diagnose. It is characterized by the subdivision of the left ventricle into two chambers by an abnormal septum or muscle band. Here, we report 12 patients with DCLV. Differential diagnoses of DCLV include four other cardiac diseases, diverticulum, aneurysm, hypertrophic cardiomyopathy, and left ventricular noncompaction. Echocardiography plays an important role in the diagnosis of this rare condition and in differentiating it from other diseases.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.