Firstly, several common vertical anti-seepage forms for modern sanitary landfill are reviewed and compared. According to the unreasonable calculation method of the wall thickness in the New Code, this paper proposes a reasonable calculation method of the wall thickness through the two engineering project cases: valley type and plain type landfill, reflecting on the reasonable choice of the vertical anti-seepage forms. For the valley type landfill where the cover layer has a certain thickness, jet grouting pile and post grouting is proposed for the anti-seepage; for the plain type landfill whose foundation is composed of clay or sandy soil, the cement mixing pile is proposed for the anti-seepage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.